NASA NTRS · 20220018966
Low Leakage Valves for Long Duration Missions
Abstract
This paper presents a status update on the low leakage cryogenic test valves currently under development at NASA’s Marshall Space Flight Center. These valves consist of a 3-inch isolation valve, a 3-inch relief valve, and an 8-inch pre-valve. Each of these valves contain a self-aligning seat and poppet design to significantly reduce the quantity of propellant flowing past the seat when the valve is in its closed state (internal leakage). This self-aligning design utilizes a metallic poppet head with five degrees of freedom and is intended to allow a valve to be more tolerant of the imperfect contacts and misalignments that are commonly found between sealing surfaces. This paper covers the test articles, facilities, objectives, and preliminary results.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Robert Walker. 2023-01-27. Low Leakage Valves for Long Duration Missions. https://ntrs.nasa.gov/citations/20220018966
Cite the original work for its findings. Save a collection to share your selection of sources.