Search NASA⌕ Search

NASA NTRS · 20230003963

Technology Developments for FIR Bolometric Detector Focal Plane Assemblies

Abstract

A discussion of recent technology developments for far-infrared bolometric detector focal plane assemblies is provided. Some of the developments include strategies for fabricating high filling fraction background limited-transition edge sensor bolometric detectors, impedance-matched absorber coatings, a micromachined blackbody source, and the capability to fabricate indium bumps on non-planar substrates.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ari Brown. Technology Developments for FIR Bolometric Detector Focal Plane Assemblies. https://ntrs.nasa.gov/citations/20230003963

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Optical leakage mitigation in ortho-mode transducer detectors for microwave applications

Ortho-mode transducers (OMT) are a commonly used method of coupling opti-cal signals between waveguides and on-chip circuitry and detectors. While the ideal OMT-waveguide coupling requires minimal disturbance to the waveguide, when used for mm-wave applications the waveguide is often slide though and the OMT probes inserted on a thin support membrane. This interface is a potential source of signal leakage and can lead to signal loss and experimental systematics (e.g. in CMB polarization experiments where lost signal can result in temperature to polarization leakage). Here we report on the development of new OMT- waveguide coupling structures with the goal of reducing leakage at the horn-to-detector-wafer interface. The pixel to pixel optical leakage due to the gap be-tween the coupling waveguide and the backshort is reduced by means of a protrusion that passes through the OMT membrane and connects the waveguide sections on each side of the wafer. High frequency electromagnetic simulations indicate that these protrusions can reduce optical leakage in the gap by ~80% percent, with a ~60% filling factor, respect to an ordinary OMT coupling without protrusion, using designs that are compatible with current fabrication processes. We describe the design of the new coupling structure including the impact of varying two key parameters: wafer to optical coupling gap and protrusion fill factor. Prototype devices have been designed that will characterize the performance of the new design using a relative measurement with varying filling factors. We describe the simulation setup and results, and present a chip layout and sample box designed to perform an initial measurement.

Detectors↗

Novel Sensors for Particle Tracking: a Contribution to the Snowmass Community Planning Exercise of 2021

Five contemporary technologies are discussed in the context of their potential roles in particle tracking for future high energy physics applications. These include sensors of the 3D configuration, in both diamond and silicon, submicron-dimension pixels, thin film detectors, and scintillating quantum dots in gallium arsenide. Drivers of the technologies include radiation hardness, excellent position, vertex, and timing resolution, simplified integration, and optimized power, cost, and material.

Detectors↗

NuSTAR Measurement of the Cosmic X-ray Background in the 3–20 keV Energy Band

We present measurements of the intensity of the cosmic X-ray background (CXB) with the Nuclear Spectroscopic Telescope Array (NuSTAR) telescope in the 3–20 keV energy range. Our method uses spatial modulation of the CXB signal on the NuSTAR detectors through the telescope’s side aperture. Based on the NuSTAR observations of selected extragalactic fields with a total exposure of 7 Ms, we have estimated the CXB 3–20 keV flux to be 2.8×10−11erg s−1cm−2deg−2, which is∼8 per cent higher than that measured withHEAO-1and consistent with the INTEGRAL measurement. The inferred CXB spectral shape in the3–20 keV energy band is consistent with the canonical model of Gruber et al. We demonstrate that the spatially modulated CXB signal measured by NuSTAR is not contaminated by systematic noise and is limited by photon statistics. The measured relative scatter of the CXB intensity between different sky directions is compatible with cosmic variance, which opens new possibilities for studying CXB anisotropy over the whole sky with NuSTAR.

Detectors↗