Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Abstract

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yolanda R Hicks, Tyler G Capil, Kathleen M Tacina. Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy. https://ntrs.nasa.gov/citations/20230007311

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

Two different configurations of a 7-point lean direct injector array were investigated. Chemiluminescence images of C2* or CH* were collected during combustion tests for insight on flame structure for the two configurations. Several inlet conditions were tested by varying the equivalence ratio or reference velocity. For the center right-hand 60 degree and outer right-hand 52 degree outers, the chemiluminescence emanating from the central pilot appeared well isolated from the outers. At the same time, a hollow region below the pilot showed little fluctuation of chemiluminescence where a central recirculation zone was present during the non-reacting tests. The central left-hand 60 degree and outer right-hand 52 degree configuration displayed a narrower structure from the pilot compared to the flatter pilot observed in the other configuration. Additionally, the right-handed outer swirlers may be responsible for the asymmetry observed with the chemiluminescence images. Both configurations showed less variation in chemiluminescence intensity as the reference velocity was increased. This was likely due to better atomization and vaporization associated with higher fuel and air flow rates.

lean direct injection↗

Fundamental Study of a 7-Element Fuel Injector Configuration for Gas Turbine Combustors, a Look at Cold Flow and Burning Measurements

As part of a parametric study in which we vary swirler angle and orientation and look at their effect on fluid mixing and combustion, we examine one configuration of a 7-point lean direct injector by looking at the non-combusting 2-D velocity field using PIV (Particle Image Velocimetry), and combusting system for chemical species using chemiluminescent imaging and flame spectroscopy. The circular 7-point array consists of axial swirlers, with the center 60 degree counterclockwise swirler surrounded by six 52 degree clockwise swirlers. The velocity results for this configuration show that the outer swirlers serve to isolate the center flow field near the injector exit. A recirculation zone forms downstream of the center swirler, but not behind the outer swirlers. The combusting results also show an isolated zone directly downstream of the center injector. The flame spectra show variation in speciation of combustion species such as OH* and CH*, and as a function of position within the combustor.

lean direct injection↗

Swirl-Venturi Lean Direct Injection Combustion Technology for Low-NOx Aero Gas Turbine Engines

This paper summarizes research on the lean direct injection (LDI) combustor concept for aero-gas turbine combustors. The focus of this paper is one particular family of lean direct injection designs, swirl-venturi lean direct injection (SV-LDI). SV-LDI is characterized by the airpath: an air swirler followed by a converging-diverging venturi. For most SV-LDI configurations, a fuel injector is inserted through the center of the air swirler, with the fuel injector tip at or near the venturi throat. Several design variables were studied. These included fuel injector tip location, air swirler blade thickness, air swirler blade angle, and fuel-air mixer size. Moving the fuel injector tip slightly upstream or downstream of the venturi throat has at most a small impact on NOx emissions. Changing the blade thickness also does not affect NOx emissions. Changing the swirler blade angle has a significant effect on NOx emissions. Decreasing swirler blade angle, and thus decreasing swirl number, decreases the NOx emissions at lower flame temperatures (below about 1800 K). However, the slope of the NOx vs. flame temperature curve is higher for lower swirl numbers. Finally, decreasing the fuel-air mixer size initially decreases NOx emissions. However, there may be an optimum fuel-air mixer size below which NOx emissions do not continue to decrease.

lean direct injection↗