Search NASASearch

NASA NTRS · 20260004481

Comparing Environmental Barrier Surface Temperature Mapping With Either A Y2SiO5:Er or Sc2SiO5:Er Temperature Sensing Layer

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

BibTeXRIS

Jeffrey I Eldridge, Michael J Presby, Kang N Lee, John A Setlock. Comparing Environmental Barrier Surface Temperature Mapping With Either A Y2SiO5:Er or Sc2SiO5:Er Temperature Sensing Layer. https://ntrs.nasa.gov/citations/20260004481

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related discoveries

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]

Boron-Based Neutron Scintillator Screen Characterization with X-Rays and Neutrons

Recent work on boron-based neutron scintillator screens suggests these screens can offer superior performance when compared to commonly used screens. Borated neutron scintillator screens perform well in terms of light output (5-6 times greater than a standard Gadox screen) and detection effi-ciency (larger than standard LiF+ZnS screens). However, previously manu-factured boron-based screens have exhibited non-uniform surface coating and a poor mixture between phosphor and converter particles. The objective of this work was to evaluate newly fabricated scintillator screens to deter-mine if enhanced fabrication methods produced a more homogeneous distribution between neutron converter and scintillation phosphor particles. Uniformity of scintillator material deposition was also inspected. This new iteration of screens appeared more uniform than previous generations with the new coating method improving surface chemistry and scintillator material homogeneity. Additionally, a new methodology for screen characterization, involving the correlation of a neutron image taken with a borated scintillator screen to X-ray computed tomography of that same screen, was demonstrated to elucidate a relationship between scintillator screen thickness and relative light output of the screen under neutron exposure. This method suggested that the ideal thickness of scintillator material was ~150 µm to maximize light output of the screen.

36 - MATERIALS SCIENCE

Density Functional Theory Analysis of Candidate Tritium Permeation Barriers for Vanadium Alloys as a Fusion Structural Material

Vanadium alloys are being considered as a candidate structural material for the breeder blanket component of future fusion reactors due to their good thermal conductivity, low activation, and chemical compatibility with FLiBe. However, vanadium has a high hydrogen solubility, resulting in hydrogen diffusion and trapping in the vanadium structural alloy and lower than expected tritium breeding ratios. To mitigate the permeation of hydrogen into the structural alloy, a tritium permeation barrier will be coated onto the vanadium alloy. Multiple materials have been proposed as candidate tritium permeation barriers, but the extent to which each of these materials impacts hydrogen diffusion and trapping is still unknown. In this project, we perform atomic-scale calculations to narrow down the list of potential tritium permeation barrier candidates and to understand the mechanisms through which hydrogen diffusion is affected in these materials.

36 MATERIALS SCIENCE