Search NASA⌕ Search

DOE OSTI · 1045668

Brayton Solar Power Conversion System

Abstract

This report contains the results of work performed in on Phase 1 and Phase 2 related to the Brayton Solar Power Conversion System project. The SolarCAT (Solar Compressed Air Turbine) is dish-engine module with compressed air energy storage. It generates 200-kWe peak power, employing a 320 sq. meter dish. Designed for multi-MW arrays, the power plant provides utility load-profile shaping as well as efficient solar power conversion. At the discretion of the utility operator, the gas turbine also operates on a wide range of fuels (bio and fossil) to supplement solar power or provide non-solar operation. A brief description of the principal subassemblies follows: • The “engine” is a compact turbo-alternator operating with only air serving as the working fluid, the lubricant, and the coolant. The turbo-alternator has been designed to be maintenance-free for the 20-year (60,000 hour) life. • The solar receiver is a tubular design incorporating mature heat exchanger design practices. ORNL has been instrumental in evaluating materials for this application. • The tracking solar concentrator (Dish) was developed and installed at Southwest Solar Technologies, by private funding. The unit constructed for Phase 2 has a collection area of approximately 320 sq meters. The critical subassemblies of the system have been fabricated and tested in Phase 2 of this program. Each subsystem was purpose-built for this new power generation system. This included a special turbo-alternator system built with air bearings, a very compact recuperator, a hybrid combustor, and a solar receiver fully integrated for installation on the SST dish. The receiver was tested alone on the dish. The extensive testing of the turbomachinery, dish and receiver conducted on this program has overcome common development issues. Furthermore, the team has worked exceptionally hard to prove the performance and cost basis of the system. Reliable subsystems have been checked-out and are ready to be move into the complete engine-dish module in Phase 3. In parallel, several economically-driven component upgrades have been identified which improve efficiency and lower cost. The project was terminated prior at the end of Phase 2, to installing the special purpose recuperated turbo-alternator on the dish.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kesseli, James (Jim), Vollnogle, Eric. 2011-07-15. Brayton Solar Power Conversion System. https://doi.org/10.2172/1045668

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY↗