DOE OSTI · 1129948
System Study: Reactor Core Isolation Cooling 1998–2012
Abstract
This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2012 for selected components were obtained from the Equipment Performance and Information Exchange (EPIX). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing trend was identified in the HPCI results. Statistically significant decreasing trends were identified for RCIC start-only and 8-hour trends.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Wierman, T. E.. 2013-10-01. System Study: Reactor Core Isolation Cooling 1998–2012. https://doi.org/10.2172/1129948
Cite the original work for its findings. Save a collection to share your selection of sources.