DOE OSTI · 1155828
Resolution study of higher-order-mode-based beam position diagnostics using custom-built electronics in strongly coupled 3.9-GHz multi-cavity accelerating module
Abstract
Beam-excited higher order modes (HOMs) can provide remote diagnostics information of the beam position and cavity misalignment. In this paper we report on recent studies on the resolution with specially selected series of modes with custom-built electronics. This constitutes the first report of measurements of these cavities in which we obtained a resolution of 20 micron in beam offset. Details of the setup of the electronics and HOM measurements are provided.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Zhang, P., Baboi, N., Jones, R. M., Eddy, N.. 2012-11-01. Resolution study of higher-order-mode-based beam position diagnostics using custom-built electronics in strongly coupled 3.9-GHz multi-cavity accelerating module. https://doi.org/10.1088/1748-0221%2F7%2F11%2Fp11016
Cite the original work for its findings. Save a collection to share your selection of sources.