Search NASA⌕ Search

DOE OSTI · 1166799

Uranium Concentration Measurement Technique Viability Analysis

Abstract

This report incorporates experimental and modelling data in support of the uranium UV-vis concentration analysis technique as applied to uranium sulfate solutions, and a short literature survey on the ‘Industry Standard’ Davies-Gray titration method for uranium analysis. A preliminary screen of a suite of contaminants that could interfere with the UV-vis measurement has revealed ruthenium to be by far the most likely to negatively impact the analysis technique, and this element is worthy of a more detailed study. Other experimental work confirm technique reproducibility and solution uniformity over time, and the potential viability of adaption to online analysis, while the application of the Guide to Uncertainty Measurements (GUM) to the UV-vis technique has been explored for the first time. Preliminary modelling analysis using GUM Workbench indicate 0.5 % technique relative uncertainty at the equivalent of two standard deviations, with an associated uncertainty ‘budget’ which provides guidance as to where the technique can be further developed to lower uncertainties.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Colletti, Lisa Michelle, May, Iain, Reilly, Sean Douglas. 2014-10-06. Uranium Concentration Measurement Technique Viability Analysis. https://doi.org/10.2172/1166799. https://searchnasa.com/record/osti%3A1166799/uranium-concentration-measurement-technique-viability-analysis

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗