Search NASA⌕ Search

DOE OSTI · 1201804

Materials Data on CsB9H14 by Materials Project

Abstract

CsB7H12(BH)2 crystallizes in the triclinic P-1 space group. The structure is one-dimensional and consists of four boranediylradical molecules and two CsB7H12 ribbons oriented in the (1, 0, 0) direction. In each CsB7H12 ribbon, Cs1+ is bonded in a 1-coordinate geometry to six H1+ atoms. There are a spread of Cs–H bond distances ranging from 2.90–3.24 Å. There are seven inequivalent B+1.67- sites. In the first B+1.67- site, B+1.67- is bonded in a distorted water-like geometry to two H1+ atoms. There is one shorter (1.20 Å) and one longer (1.34 Å) B–H bond length. In the second B+1.67- site, B+1.67- is bonded in a distorted bent 120 degrees geometry to two H1+ atoms. Both B–H bond lengths are 1.21 Å. In the third B+1.67- site, B+1.67- is bonded in a distorted water-like geometry to two H1+ atoms. There is one shorter (1.20 Å) and one longer (1.30 Å) B–H bond length. In the fourth B+1.67- site, B+1.67- is bonded in a distorted trigonal non-coplanar geometry to three H1+ atoms. There are a spread of B–H bond distances ranging from 1.21–1.37 Å. In the fifth B+1.67- site, B+1.67- is bonded in a distorted water-like geometry to two H1+ atoms. There is one shorter (1.20 Å) and one longer (1.38 Å) B–H bond length. In the sixth B+1.67- site, B+1.67- is bonded in a distorted trigonal non-coplanar geometry to three H1+ atoms. There are a spread of B–H bond distances ranging from 1.19–1.33 Å. In the seventh B+1.67- site, B+1.67- is bonded in a single-bond geometry to one H1+ atom. The B–H bond length is 1.20 Å. There are twelve inequivalent H1+ sites. In the first H1+ site, H1+ is bonded in a single-bond geometry to one Cs1+ and one B+1.67- atom. In the second H1+ site, H1+ is bonded in a single-bond geometry to one B+1.67- atom. In the third H1+ site, H1+ is bonded in a single-bond geometry to one Cs1+ and one B+1.67- atom. In the fourth H1+ site, H1+ is bonded in a single-bond geometry to one B+1.67- atom. In the fifth H1+ site, H1+ is bonded in a single-bond geometry to one Cs1+ and one B+1.67- atom. In the sixth H1+ site, H1+ is bonded in a single-bond geometry to one B+1.67- atom. In the seventh H1+ site, H1+ is bonded in an L-shaped geometry to two B+1.67- atoms. In the eighth H1+ site, H1+ is bonded in an L-shaped geometry to two B+1.67- atoms. In the ninth H1+ site, H1+ is bonded in a single-bond geometry to one Cs1+ and one B+1.67- atom. In the tenth H1+ site, H1+ is bonded in a single-bond geometry to one Cs1+ and one B+1.67- atom. In the eleventh H1+ site, H1+ is bonded in a distorted single-bond geometry to one Cs1+ and one B+1.67- atom. In the twelfth H1+ site, H1+ is bonded in an L-shaped geometry to two B+1.67- atoms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

2020-04-29. Materials Data on CsB9H14 by Materials Project. https://doi.org/10.17188/1201804

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗