DOE OSTI · 1260460
Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2014
Abstract
This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The TDP failure modes considered are failure to start (FTS), failure to run less than or equal to one hour (FTR=1H), failure to run more than one hour (FTR>1H), and normally running systems FTS and failure to run (FTR). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. Statistically significant increasing trends were identified for TDP unavailability, for frequency of start demands for standby TDPs, and for run hours in the first hour after start. Statistically significant decreasing trends were identified for start demands for normally running TDPs, and for run hours per reactor critical year for normally running TDPs.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Schroeder, John Alton. 2015-11-01. Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2014. https://doi.org/10.2172/1260460
Cite the original work for its findings. Save a collection to share your selection of sources.