Bragg coherent x-ray diffractive imaging is a powerful technique for investigating dynamic nanoscale processes in nanoparticles immersed in reactive, realistic environments. Its temporal resolution is limited, however, by the oversampling requirements of three-dimensional phase retrieval. Here, we show that incorporating the entire measurement time series, which is typically a continuous physical process, into phase retrieval allows the oversampling requirement at each time step to be reduced, leading to a subsequent improvement in the temporal resolution by a factor of 2-20 times. The increased time resolution will allow imaging of faster dynamics and of radiation-dose-sensitive samples. Furthermore, this approach, which we call "chrono CDI," may find use in improving the time resolution in other imaging techniques.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Ulvestad, A., Tripathi, A., Hruszkewycz, S. O., Cha, W., Wild, S. M., Stephenson, G. B., Fuoss, P. H.. 2016-05-19. Coherent diffractive imaging of time-evolving samples with improved temporal resolution. https://doi.org/10.1103/physrevb.93.184105. https://searchnasa.com/record/osti%3A1275788/coherent-diffractive-imaging-of-time-evolving-samples-with-improved-temporal-resolution