DOE OSTI · 1377555
When does atomic resolution plan view imaging of surfaces work?
Abstract
We present that surface structures that are different from the corresponding bulk, reconstructions, are exceedingly difficult to characterize with most experimental methods. Scanning tunneling microscopy, the workhorse for imaging complex surface structures of metals and semiconductors, is not as effective for oxides and other insulating materials. This paper details the use of transmission electron microscopy plan view imaging in conjunction with image processing for solving complex surface structures. We address the issue of extracting the surface structure from a weak signal with a large bulk contribution. This method requires the sample to be thin enough for kinematical assumptions to be valid. The analysis was performed on two sets of data, c(6×2) on the (100) surface and (3×3) on the (111) surface of SrTiO 3 , and was unsuccessful in the latter due to the thickness of the sample and a lack of inversion symmetry. In conclusion, the limits and the functionality of this method are discussed.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Koirala, Pratik, Lin, Yuyuan, Ciston, Jim, Marks, Laurence D.. 2016-08-06. When does atomic resolution plan view imaging of surfaces work?. https://doi.org/10.1016/j.ultramic.2016.08.001
Cite the original work for its findings. Save a collection to share your selection of sources.