DOE OSTI · 1395865
Identifying Defects with Guided Algorithms in Bragg Coherent Diffractive Imaging
Abstract
In this study, crystallographic defects such as dislocations can significantly alter material properties and functionality. However, imaging these imperfections during operation remains challenging due to the short length scales involved and the reactive environments of interest. Bragg coherent diffractive imaging (BCDI) has emerged as a powerful tool capable of identifying dislocations, twin domains, and other defects in 3D detail with nanometer spatial resolution within nanocrystals and grains in reactive environments. However, BCDI relies on phase retrieval algorithms that can fail to accurately reconstruct the defect network. Here, we use numerical simulations to explore different guided phase retrieval algorithms for imaging defective crystals using BCDI. We explore different defect types, defect densities, Bragg peaks, and guided algorithm fitness metrics as a function of signal-to-noise ratio. Based on these results, we offer a general prescription for phasing of defective crystals with no a prior knowledge.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Ulvestad, A., Nashed, Y., Beutier, G., Verdier, M., Hruszkewycz, S. O., Dupraz, M.. 2017-08-30. Identifying Defects with Guided Algorithms in Bragg Coherent Diffractive Imaging. https://doi.org/10.1038/s41598-017-09582-7