Search NASA⌕ Search

DOE OSTI · 1409270

Initial Verification and Validation Assessment for VERA

Abstract

The Virtual Environment for Reactor Applications (VERA) code suite is assessed in terms of capability and credibility against the Consortium for Advanced Simulation of Light Water Reactors (CASL) Verification and Validation Plan (presented herein) in the context of three selected challenge problems: CRUD-Induced Power Shift (CIPS), Departure from Nucleate Boiling (DNB), and Pellet-Clad Interaction (PCI). Capability refers to evidence of required functionality for capturing phenomena of interest while capability refers to the evidence that provides confidence in the calculated results. For this assessment, each challenge problem defines a set of phenomenological requirements against which the VERA software is assessed. This approach, in turn, enables the focused assessment of only those capabilities relevant to the challenge problem. The evaluation of VERA against the challenge problem requirements represents a capability assessment. The mechanism for assessment is the Sandia-developed Predictive Capability Maturity Model (PCMM) that, for this assessment, evaluates VERA on 8 major criteria: (1) Representation and Geometric Fidelity, (2) Physics and Material Model Fidelity, (3) Software Quality Assurance and Engineering, (4) Code Verification, (5) Solution Verification, (6) Separate Effects Model Validation, (7) Integral Effects Model Validation, and (8) Uncertainty Quantification. For each attribute, a maturity score from zero to three is assigned in the context of each challenge problem. The evaluation of these eight elements constitutes the credibility assessment for VERA.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dinh, Nam, Athe, Paridhi, Jones, Christopher, Hetzler, Adam, Sieger, Matt. 2017-04-01. Initial Verification and Validation Assessment for VERA. https://doi.org/10.2172/1409270

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗