Search NASA⌕ Search

DOE OSTI · 1464735

CRADA: Data Acquisition and Tomographic Software Development

Abstract

Dr. Raymond R. Raylman, Professor and Vice Chair for Research, Radiology Department at WVU was the Principal Investigator for the project. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and the chief contact with WVU. The responsibility of Jefferson Lab was to facilitate optimization of data acquisition software, conversion of JLab Fortran iterative positron emission mammography computer code to C++ and to act as a computer code repository. During the two year project interactions and exchange of information was directed by Dr. Raylman and Dr. Wesienberger. WVU provided the expertise that allowed JLab to continue development of the current JLab data acquisition software referred to as JDAQ. JDAQ is a highly flexible Java language based data acquisition tool that helps to minimize software induced dead-time while maintaining the highest possible data rates from a JLab built FPGA based analog-to-digital convertor (ADC). JDAQ interfaces directly with the FPGA based multi-channel ADCs. Using JDAQ it is possible process data from a number of different detector types such as the PET systems at WVU. Because of the inherent flexibility of our processing software, we are also able adjust detector readout parameters during operation to provide the best possible data presentation and calibration parameters. To accommodate the high rate nature of PET detector systems JDAQ was designed to be scalable across an Ethernet network as well as for multi-cpu computer systems, and it also has the capability to synchronize many ADCs connected to multiple computers. During the project WVU will provided iterative reconstruction algorithm expertise and Fortran programming assistance to facilitate the conversion to C++ of a JLab developed Fortran positron emission mammography (PEM) reconstruction code. Also WVU provided acceptance testing of the new C++ based PEM reconstruction code. The PEM code is a maximization (MLEM) image reconstruction program that created images from the list-mode data acquired from the PET system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Raylman, Raymond R.. 2015-01-14. CRADA: Data Acquisition and Tomographic Software Development. https://doi.org/10.2172/1464735

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

TANTE: Time-adaptive operator learning via neural Taylor expansion

Operator learning for time-dependent partial differential equations (PDEs) has seen rapid progress in recent years, enabling efficient approximation of complex spatiotemporal dynamics. However, most existing methods rely on fixed time step sizes during rollout, which limits their ability to adapt to varying temporal complexity and often leads to error accumulation. In this work, we propose the Time-Adaptive Transformer with Neural Taylor Expansion (TANTE), a novel operator-learning framework that produces continuous-time predictions with adaptive step sizes. TANTE predicts future states by performing a Taylor expansion at the current state, where neural networks learn both the higher-order temporal derivatives and the local radius of convergence. This allows the model to dynamically adjust its rollout based on the local behavior of the solution, thereby reducing cumulative error and improving computational efficiency. We demonstrate the effectiveness of TANTE across a wide range of PDE benchmarks, achieving superior accuracy and adaptability compared to fixed-step baselines, delivering accuracy gains of 60-80 % and speed-ups of 30-40 % at inference time.

97 MATHEMATICS AND COMPUTING↗

Structured illumination for surface-resolved grazing-incidence X-ray scattering

Grazing-incidence (GI) scattering techniques are widely used to characterize thin films, offering high surface sensitivity and insight into morphology and structure. However, these approaches typically provide statistical averaged information due to elongated footprint or limited spatial resolution due to beam size. Here we introduce a method that combines structured illumination with GI X-ray scattering and leverages our computational imaging approach to resolve local structural details. We demonstrate that our method captures local features of an organic semiconductor thin film without the need for sample rotation as in tomography. The method expands GI techniques from statistical averaging to high-resolution imaging, thereby providing the capability for detailed analysis of local material properties, such as domain shape, orientation and polymorphism, which are critical for advancing material design towards more efficient and tailored materials.

97 MATHEMATICS AND COMPUTING↗