Search NASA⌕ Search

DOE OSTI · 1487333

Developing a Framework for Reference Cell Standards for PV Resource Applications

Abstract

Quantifying and predicting electricity production from photovoltaic (PV) systems is based on measured or modeled irradiance data. These solar resource data consist of global horizontal irradiance, global tilted irradiance, direct normal irradiance, and diffuse horizontal irradiance, which are either derived from satellite observations validated against ground-based measurements or directly obtained from ground-based measurements. The ground-based measurements are made using thermopile or photodiode radiometers. For a PV plant, the efficiency of the energy production is verified by comparing measured output with the modeled production, which is computed using either modeled or measured irradiance data. Thus, plant performance assessments typically include the uncertainty of the transposition and, in some cases, decomposition of a given irradiance to convert to the appropriate plane-of-array (POA) irradiance corresponding to the orientation of the PV installation. Additionally, the various types of uncertainty in radiometric measurements or the modeled irradiance and the PV module specifications influence the model results and thereby further increase the uncertainty. An alternative method of assessing the PV system performance has been to use reference cells to measure the "PV resource." When used to calculate PV performance ratios, there are inherent systematic differences between radiometers and reference cells, such as spectral, directional, temperature, time responses, nonstability, and nonlinearity differences. Reference cells tend to mimic the performance and characteristics of a PV module more closely. In this report, a framework is proposed to develop standards that will better quantify and characterize the use of reference cells for PV resource measurements. The measurement from an appropriate reference cell in the POA correlates closely with the plant performance, reduces the number of modeling steps needed to simulate PV performance, and hence reduces the uncertainties of the comparisons. Because technologically matched reference cells and PV modules respond similarly to each wavelength of light that composes the incident solar radiation, the uncertainty associated with the changing spectral distribution of incident radiation during the day and year can be greatly reduced. This will reduce the overall uncertainty in estimated PV performance. The same can be said for the angle-of-incidence effects because the reference cells are deployed in the same POA as the PV module. At that point, the main sources of uncertainty are in modeling the temperature effect differences between the reference cells and the PV module and accounting for the difference between the short-circuit current monitored by the reference cells and max power point current and voltage at which the PV module operates. These sources of uncertainty are also associated with typical irradiance measurements made by pyranometers and pyrheliometers; however, typical irradiance measurements also include uncertainties associated with the spectral mismatch between thermopile or photodiode pyranometers and the PV module, which are minimized with the use of reference cells. To enhance the use of reference cells for resource assessment, we identify the necessary data, characteristics, and calibration methodologies of reference cells and how to standardize the use of these data and methods. Further, as we develop this framework, the classification of reference cells will be essential to provide guidance for selecting PV reference cells appropriate for a specific application. As we address the calibration and sources of uncertainties of reference cells, classification schemes and expected limits of performance with respect to certain parameters become important.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Habte, Aron M., Sengupta, Manajit, Xie, Yu, Dooraghi, Michael R., Reda, Ibrahim M., Driesse, Anton, Gueymard, Christian, Wilbert, Stefan, Vignola, Frank. 2018-12-12. Developing a Framework for Reference Cell Standards for PV Resource Applications. https://doi.org/10.2172/1487333

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.

14 SOLAR ENERGY↗