Advanced High Torque Density Magnetically Geared Generator

Abstract

The objective of this research project was to investigate the fundamental torque density limitations of multistage flux focusing magnetic gears and magnetically geared direct-drive generators for wind turbines. Magnetic gears create non-contact speed amplification by modulating the air-gap magnetic field harmonics created by magnetic rotors. By integrating a stator into the magnetic gear structure a very high torque density direct-drive generator can be created. Magnetic geared systems offer unique capabilities that are currently not available using existing mechanically geared systems, such as overload protection. Magnetic gears also offer the potential for higher reliability, higher efficiency and quieter operation than is currently achievable using a mechanically geared generator. By increasing reliability and design life magnetic gears could decrease the overall life-cycle costs when compared with equivalent mechanical or direct-drive drivetrains. This research project investigated and experimentally testing two sub-scale magnetic gearboxes (0.12 m diameter) and two large diameter magnetic gearboxes (0.56m and 0.63m diameter). The goal of the project was to demonstrate a torque density >300Nm/L for a multistage magnetic gearbox with integrated stator. A nested multistage magnetic gear structure was first proposed and studied. However, it was shown that the nested design greatly increased mechanical complexity and therefore a two-stage series typology was utilized. A multi-stage magnetic gear with a 59:1 gear ratio was successfully experimentally tested. A peak torque of 4.25 kN·m was measured and this resulted in an overall active region torque density of 141 N·m/L (when including support rings). The torque density was significantly reduced from what was computed using 2-D electromagnetic analysis. This reduction was due to the 3-D edge effects, increased power losses and the inclusion of additional mechanical support rings as well as other mechanical assembly design changes. At large diameters contiguous lamination parts could not be fabricated and so a segmented laminated rotor design had to be used. This reduced the mechanical strength of the design when compared to small diameter magnetic gears and resulted in the need for the addition of mechanical support rings to prevent deflection. The final experimentally tested design also had a high torque ripple and the power loss within the magnetic gear did not change significantly with load. This therefore resulted in the efficiency being high only at peak loads. Despite not experimentally achieving the 2-D calculated high torque density the analysis has shown that the problems encountered with the scaling can be overcome with careful design changes. For example, understanding the unique mechanical deflection requirements during the electromagnetic design of the large diameter magnetic gears is key to achieving both a high torque density based on the electromagnetic analysis and a high torque density based on the mechanical support needs. Furthermore, ensuring that end plates are made of non-conductive material and minimizing other conductive support elements within the magnetic structure is a key requirement for reducing eddy current losses. In summary, if the mechanical design can be made more robust and eddy current loss mitigation strategies are used in the mechanical design phase then the magnetic gear is capable of being scaled up whilst operating at a very high torque density. This will then enable it to be potentially performance and cost competitive with alternative direct-drive and mechanically geared wind turbine drivetrains.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bird, Jonathan, Williams, Wesley. 2018-06-30. Advanced High Torque Density Magnetically Geared Generator. https://doi.org/10.2172/1494152

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

An adaptive model-free robotic force control strategy for hydrodynamic real-time hybrid simulation of floating offshore wind turbines

Real-time hybrid simulation (RTHS) - a cyber-physical testing approach - promises to enhance the simulation fidelity of the model-scale experiments used to prototype floating offshore wind turbines (FOWTs). In hydrodynamic RTHS (hydro-RTHS), actuators emulate aerodynamic forces on model-scale FOWT specimens subjected to physical waves in a hydrodynamic laboratory. Robotic arms are promising candidates for actuation in hydro-RTHS due to their compact multi-degree-of-freedom (DOF) capabilities. Unlike classical RTHS for seismic applications, which typically relies on displacement control, hydro-RTHS requires 6-DOF force control on newly designed floating prototypes in a model-scale setting, which presents significant challenges, including modeling uncertainties, directional asymmetry, configuration drift, bandwidth limitations, and time-varying delays. To mitigate these constraints without extensive pre-test calibration, this study proposes an adaptive model-free robotic force control strategy that combines task-space explicit force control with a secondary joint-space pose-keeping task. The Adaptive Feedforward Compensator (AFC) is integrated into the force control loop to compensate for time-varying delay. Experimental testing was conducted using a Franka Emika Panda robotic arm with a 1:50 scale FOWT specimen under operational wind and wave conditions. Results demonstrate stable and consistent 6-DOF force tracking. Effective delay compensation was observed, with low-frequency delay reductions ranging from 71.4% to 91.8% and improvements in low-frequency surge force tracking of 25.0% to 52.1%. This study enhances robotic actuation performance in hydro-RTHS and introduces a force control strategy that supports reliable robotic operation in uncertain floating environments. Future work will explore disturbance-observer mechanisms to further enhance wave rejection capabilities under extreme wind and wave conditions.

17 WIND ENERGY↗

Computational capacity in hydrodynamic real-time hybrid simulation applied to simulate the dynamic response of floating offshore wind turbines

Real-time hybrid simulation (RTHS) mitigates similitude distortions in model-scale tests of floating offshore wind turbines (FOWTs) by coupling physical experiments with numerical models in real time. The coupling requires faster-than-real-time numerical computations to satisfy temporal similitude with the physical experiment, presenting a bottleneck for using more complex numerical models in RTHS. This paper presents a hydrodynamic-RTHS (hydro-RTHS) framework for FOWTs that simulates the hydrodynamics physically and the aerodynamics numerically with sensor feedback from the physical testing. The framework adapts the three-loop hardware architecture to leverage greater computational resources and mitigate strict temporal requirements, enabling more computationally demanding numerical analyses in hydro-RTHS. The three-loop hardware architecture integrates multiple machines, each dedicated to either numerical analysis or RTHS controls, with a rate-transition algorithm to synchronize the tasks executed across the different machine processors. Virtual and physical tests verified and validated the hydro-RTHS framework, respectively. The ”virtual” tests, which approximates the physical domain numerically, verified the RTHS framework with respect to a numerical full-scale complete FOWT model simulated in the open-source software, OpenFAST. The virtual tests were able to maintain comparable control signals while enabling greater computational resources for the numerical calculations. Real-world physical tests demonstrated that the hydro-RTHS framework computes aerodynamic forces similar to the complete OpenFAST model, validating the hydro-RTHS framework using the three-loop hardware architecture. Findings show that the hydro-RTHS framework with the three-loop hardware architecture is computationally efficient, with reserve capacity to simulate more complex problems due to the customized software, hardware, and rate-transition algorithm.

17 WIND ENERGY↗

Statistical Correlation of Heliostat Pointing Deviation With Wind

This work was carried out as part of the Heliostat Consortium (HelioCon) Field Deployment subtask with the aim to develop a reduced order model framework for correlating wind speed and pointing deviation of a heliostat facet. There are only sparse field measurements of heliostat pointing deviations and accompanying wind conditions published in the literature. Heliostat test standards, such as IEC 62862-4-3, propose a suite of tests including laser pointing repeatability at wind speeds below 4 m/s, and provide technical requirements for heliostat slope and tracking deviations in coarse average wind speed bins of 4 m/s, 6 m/s, and 8 m/s. In addressing the gap of the variation of heliostat pointing deviation with wind speed, field measurements of laser pointing on a grid target and wind conditions were analyzed in this study at the Third-Party Metrology Platform at the National Laboratory of the Rockies (NLR) Flatirons Campus. Horizontal pointing deviations were found to follow a logarithmic relationship with peak wind speed, whereas vertical pointing deviations follow an exponential relationship with peak wind speed. Both horizontal and vertical pointing deviations also follow a second order polynomial relationship, as expected from the proportionality of elastic loads and deformations with the square of wind speed. The results indicate that heliostat facet pointing deviations in the vertical direction increase at a faster rate than in the horizontal direction with increasing wind speed over the tested range, however these are dependent on the heliostat structural design. Next steps are recommended for additional field measurements to confirm a linear relationship of pointing deviation with applied moment on a heliostat facet, and to distinguish between gravity-induced and wind-induced pointing deviations at different elevation angles. The derived correlations in the preliminary analysis in this report serve as a case study for heliostat developers and plant operators to estimate the wind-induced pointing deviations and their variation with peak gust wind speed. Next steps in future work would recommend higher resolution and longer duration datasets for different elevation angles and wind directions to reduce uncertainties and variance of collected laser beam spot data and their correlations with bin-averaged wind speed.

17 WIND ENERGY↗