Linear fitting of multi-threshold counting data

Abstract

The present disclosure provides a system and method for efficiently mining multi-threshold measurements acquired using photon counting pixel-array detectors for spectral imaging and diffraction analyses. Images of X-ray intensity as a function of X-ray energy were recorded on a 6 megapixel X-ray photon counting array detector through linear fitting of the measured counts recorded as a function of counting threshold. An analytical model is disclosed for describing the probability density of detected voltage, utilizing fractional photon counting to account for edge/corner effects from voltage plumes that spread across multiple pixels. Three-parameter fits to the model were independently performed for each pixel in the array for X-ray scattering images acquired for 13.5 keV and 15.0 keV X-ray energies. From the established pixel responses, multi-threshold composite images produced from the sum of 13.5 keV and 15.0 keV data can be analytically separated to recover the monochromatic images through simple linear fitting.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Simpson, Garth Jason, Muir, Ryan Douglas, Pogranichniy, Nicholas Roman. 2018-12-04. Linear fitting of multi-threshold counting data. https://www.osti.gov/biblio/1496604

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗