This study looks at forecasted dynamic line ratings in southern Idaho by using data from the High Resolution Rapid Refresh (HRRR) model for forecasted weather conditions. The HRRR model can provide accurate 18- hour forecasts with a 15-minute temporal resolution. Typical static ratings used for over head transmission lines use overly conservative assumptions for local weather conditions, such as using the maximum solar irradiance or temperature measured during the summer combined with low wind speed for an entire season. The HRRR forecast model used here has a high spatial resolution to provide local forecast conditions along the entire length of a transmission line. The area that is of interest in this study is in southern Idaho spanning a total of 15,000 square kilometers. The forecasted weather data is coupled with a computational fluid dynamics model of the wind in the region to improve the resolution to an even finer scale for resolving local convective cooling rates on each individual transmission line midpoint span. This high fidelity approach can be used to find the minimum ampacity limit across all given midpoints of a transmission line to determine the absolute minimum to be used for the line rating. The ability to increase the line rating above the conservative static approach with the forecasted weather data provides a large potential to alleviate congestion and provide data for the utility market transactions. Furthermore, this study shows that for the region of interest, using forecasted weather data coupled with CFD modeling will calculate DLR ampacity rating above static about 90% of the time, with only a small relative error in the forecasted ampacity over time.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Abboud, Alexander W., Fenton, Kenneth R., Lehmer, Jacob P., Fehringer, Benjamin A., Gentle, Jake P., McJunkin, Timothy R., Le Blanc, Katya L., Petty, Melissa A., Wandishin, Matthew S.. 2019-02-08. Coupling computational fluid dynamics with the high resolution rapid refresh model for forecasting dynamic line ratings. https://doi.org/10.1016/j.epsr.2019.01.035. https://searchnasa.com/record/osti%3A1498106/coupling-computational-fluid-dynamics-with-the-high-resolution-rapid-refresh-model-for-forecasting-d

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Nodal capacity expansion planning with flexible large-scale load siting

We propose explicitly incorporating large-scale load siting into a stochastic nodal power system capacity expansion planning model that concurrently co-optimizes generation, transmission, and storage expansion. The potential operational flexibility of some of these large loads is also taken into account by considering them as consisting of a set of tranches with different reliability requirements, which are modeled as a constraint on expected served energy across operational scenarios. We implement our model as a two-stage stochastic mixed-integer optimization problem with cross-scenario expectation constraints. To overcome the challenge of scalability, we build upon existing work to implement this model on a high performance computing platform and exploit scenario parallelization using an augmented Progressive Hedging Algorithm. The algorithm is implemented using the bounding features of mpisppy, which have shown to provide satisfactory provable optimality gaps despite the absence of theoretical guarantees of convergence. We test our approach and assess the value of this proactive planning framework on total system cost and reliability metrics using realistic testcases geographically assigned to San Diego and South Carolina, with datacenter and direct air capture facilities as large loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From zonal to nodal capacity expansion planning: Spatial aggregation impacts on a realistic test-case

Solving power system capacity expansion planning (CEP) problems at realistic spatial resolutions is computationally challenging. Thus, a common practice is to solve CEP over zonal models with low spatial resolution rather than over full-scale nodal power networks. Due to improvements in solving large-scale stochastic mixed integer programs, these computational limitations are becoming less relevant, and the assumption that zonal models are realistic and useful approximations of nodal CEP is worth revisiting. Here, this work is the first to conduct a systematic computational study on the assumption that spatial aggregation can reasonably be used for ISO-scale CEP. By considering a realistic, large-scale test network based on the state of California with over 8000 buses, we find that well-designed small spatial aggregations can yield good approximations but that coarser zonal models may result in large distortions of investment decisions, e.g., capacity under-investment of up to 41% for the lowest resolution model considered.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.