Reasonable Beam Deviation Envelope for Ray-tracing
Abstract
At NSLS-II the unused dipole radiation is intercepted by the photon absorbers installed inside the vacuum chamber. The water-cooled absorbers are designed to take away the heat therefore the temperature is kept within the safety limit. However, if the beam orbit is severely perturbed, the radiation fan could pass through the geometry and strikes on the vacuum chamber components. This ray-leakage is a possible reason of the accelerator component temperature rise observed during the high-current operations. The goal of this work is to find the maximum beam deviation at the dipole hence ray-tracing can be re-examined under the operational constraints. The beam is confined to the orbit by the bending and focusing magnets. At NSLS-II the orbit is further controlled by a real time orbit feedback loop. Beam could be lost in any unpredictable direction if the magnet malfunctions. Consequently reasonable assumptions must be made to define the deviation envelope. It was determined that the dipole radiation is not powerful enough to cause damage within 10 ms, for example, if the rf power is shut off and the beam deviates from the orbit. Therefore we consider the radiation produced by the stored beam only; temporarily processes, such as unstable oscillating beam, should not be a concern. The orbit of the stored beam can be altered during magnet failures. The dipole current is interlocked to a small range of ±2% from the nominal value. If the dipole current changes slowly the beam energy automatically adjusts and the orbit remains the same. If the dipole current changes rapidly the beam will not be stable. Therefore dipole variation need not to be considered. For the other magnets we consider one magnet failure at a time because it is unlikely that two fail at the same time. It was found that the beam lifetime drops dramatically if one quadrupole power supply is turned off; therefore this scenario does not meet the stable beam condition. The current of one quadrupole could drop but will not result in orbit change with the feedback on. Beam could survive if one sextupole power supply is turned off, but the orbit will not be changed. Magnet could partially fail, for example, one or part of the coil shorts due to break-down. This is a low probability event and will not be considered. During daily operations the orbit is changed by the correctors and the rf frequency. In this work the correctors and the rf frequency are varied to explore the deviation envelope.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Guo, Weiming. 2018-04-27. Reasonable Beam Deviation Envelope for Ray-tracing. https://doi.org/10.2172/1504391
Cite the original work for its findings. Save a collection to share your selection of sources.