A computational fluid dynamics simulation framework for ventricular catheter design optimization

Abstract

OBJECTIVE Cerebrospinal fluid (CSF) shunts are the primary treatment for patients suffering from hydrocephalus. While proven effective in symptom relief, these shunt systems are plagued by high failure rates and often require repeated revision surgeries to replace malfunctioning components. One of the leading causes of CSF shunt failure is obstruction of the ventricular catheter by aggregations of cells, proteins, blood clots, or fronds of choroid plexus that occlude the catheter’s small inlet holes or even the full internal catheter lumen. Such obstructions can disrupt CSF diversion out of the ventricular system or impede it entirely. Previous studies have suggested that altering the catheter’s fluid dynamics may help to reduce the likelihood of complete ventricular catheter failure caused by obstruction. However, systematic correlation between a ventricular catheter’s design parameters and its performance, specifically its likelihood to become occluded, still remains unknown. Therefore, an automated, open-source computational fluid dynamics (CFD) simulation framework was developed for use in the medical community to determine optimized ventricular catheter designs and to rapidly explore parameter influence for a given flow objective. METHODS The computational framework was developed by coupling a 3D CFD solver and an iterative optimization algorithm and was implemented in a high-performance computing environment. The capabilities of the framework were demonstrated by computing an optimized ventricular catheter design that provides uniform flow rates through the catheter’s inlet holes, a common design objective in the literature. The baseline computational model was validated using 3D nuclear imaging to provide flow velocities at the inlet holes and through the catheter. RESULTS The optimized catheter design achieved through use of the automated simulation framework improved significantly on previous attempts to reach a uniform inlet flow rate distribution using the standard catheter hole configuration as a baseline. While the standard ventricular catheter design featuring uniform inlet hole diameters and hole spacing has a standard deviation of 14.27% for the inlet flow rates, the optimized design has a standard deviation of 0.30%. CONCLUSIONS This customizable framework, paired with high-performance computing, provides a rapid method of design testing to solve complex flow problems. While a relatively simplified ventricular catheter model was used to demonstrate the framework, the computational approach is applicable to any baseline catheter model, and it is easily adapted to optimize catheters for the unique needs of different patients as well as for other fluid-based medical devices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Weisenberg, Sofy H., TerMaath, Stephanie C., Barbier, Charlotte N., Hill, Judith C., Killeffer, James A.. 2018-10-01. A computational fluid dynamics simulation framework for ventricular catheter design optimization. https://doi.org/10.3171/2017.5.jns161882

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Calibration of multisite raters for prospective visual reads of amyloid PET scans

Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.

Neurosciences & Neurology↗

Tau PET positivity in individuals with and without cognitive impairment varies with age, amyloid-β status, APOE genotype and sex

Abstract Tau positron emission tomography (PET) imaging allows in vivo detection of tau proteinopathy in Alzheimer’s disease, which is associated with neurodegeneration and cognitive decline. Understanding how demographic, clinical and genetic factors relate to tau PET positivity will facilitate its use for clinical practice and research. Here we conducted an analysis of 42 cohorts worldwide (N = 12,048), including 7,394 cognitively unimpaired (CU) participants, 2,177 participants with mild cognitive impairment (MCI) and 2,477 participants with dementia. We found that from age 60 years to 80 years, tau PET positivity in a temporal composite region increased from 1.1% to 4.4% among CU amyloid-β (Aβ)-negative participants and from 17.4% to 22.2% among CU Aβ-positive participants. Across the same age span, tau PET positivity decreased from 68.0% to 52.9% in participants with MCI and from 91.5% to 74.6% in participants with dementia. Age, Aβ status,APOEε4 carriership and female sex were all associated with a higher prevalence of tau PET positivity across groups.APOEε4 carriership in CU individuals lowered the age at onset of both Aβ positivity and tau positivity by decades. Finally, we replicated these associations in an independent autopsy dataset (N = 5,072 from 3 cohorts).

Neurosciences & Neurology↗