DOE OSTI · 1566094
Monitoring an Electro-Refining Process (Rev. 1)
Abstract
In this report we examine measurements from two different sensors for detecting a diversion of plutonium in an electro-refining (ER) process. One method is based on counts from a high dose neutron detector (HDND). The other is based on spectra from a micro-calorimeter sensor. The spectra come from ER-salt, fission product waste, and from a source term. The goal is to differentiate between normal and off normal operating conditions using neutron counts or changes in counts in the spectra. Unfortunately, there is no electro-refining process that we can actually monitor to obtain real data from various operating conditions so we will use simulated data to illustrate our approach.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Fugate, Michael Lynn, Key, Brian P., Tutt, James Robert. 2019-09-30. Monitoring an Electro-Refining Process (Rev. 1). https://doi.org/10.2172/1566094
Cite the original work for its findings. Save a collection to share your selection of sources.