Search NASA⌕ Search

DOE OSTI · 1598874

Comprehensive geoneutrino analysis with Borexino

Abstract

This paper presents a comprehensive geoneutrino measurement using the Borexino detector, located at Laboratori Nazionali del Gran Sasso (LNGS) in Italy. The analysis is the result of 3262.74 days of data between December 2007 and April 2019. The paper describes improved analysis techniques and optimized data selection, which includes enlarged fiducial volume and sophisticated cosmogenic veto. The reported exposure of ( 1.29 ± 0.05 ) × 10 32 protons × year represents an increase by a factor of two over a previous Borexino analysis reported in 2015. By observing 52.6 - 8.6 + 9.4 ( stat ) - 2.1 + 2.7 ( sys ) geoneutrinos (68% interval) from U 238 and Th 232 , a geoneutrino signal of 47.0 - 7.7 + 8.4 ( stat ) - 1.9 + 2.4 ( sys ) TNU with - 17.2 + 18.3 % total precision was obtained. This result assumes the same Th/U mass ratio as found in chondritic CI meteorites but compatible results were found when contributions from U 238 and Th 232 were both fit as free parameters. Antineutrino background from reactors is fit unconstrained and found compatible with the expectations. The null-hypothesis of observing a geoneutrino signal from the mantle is excluded at a 99.0% C.L. when exploiting detailed knowledge of the local crust near the experimental site. Measured mantle signal of 21.2 - 9.0 + 9.5 ( stat ) - 0.9 + 1.1 ( sys ) TNU corresponds to the production of a radiogenic heat of 24.6 - 10.4 + 11.1 TW (68% interval) from U 238 and Th 232 in the mantle. Assuming 18% contribution of K 40 in the mantle and 8.1 - 1.4 + 1.9 TW of total radiogenic heat of the lithosphere, the Borexino estimate of the total radiogenic heat of the Earth is 38.2 - 12.7 + 13.6 TW , which corresponds to the convective Urey ratio of 0.78 - 0.28 + 0.41 . These values are compatible with different geological predictions, however there is a ~ 2.4 σ tension with those Earth models which predict the lowest concentration of heat-producing elements in the mantle. In addition, by constraining the number of expected reactor antineutrino events, the existence of a hypothetical georeactor at the center of the Earth having power greater than 2.4 TW is excluded at 95% C.L. Particular attention is given to the description of all analysis details which should be of interest for the next generation of geoneutrino measurements using liquid scintillator detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Agostini, M., Altenmüller, K., Appel, S., Atroshchenko, V., Bagdasarian, Z., Basilico, D., Bellini, G., Benziger, J., Bick, D., Bonfini, G., Bravo, D., Caccianiga, B., Calaprice, F., Caminata, A., Cappelli, L., Cavalcante, P., Cavanna, F., Chepurnov, A., Choi, K., D’Angelo, D., Davini, S., Derbin, A., Di Giacinto, A., Di Marcello, V., Ding, X. F., Di Ludovico, A., Di Noto, L., Drachnev, I., Fiorentini, G., Formozov, A., Franco, D., Gabriele, F., Galbiati, C., Gschwender, M., Ghiano, C., Giammarchi, M., Goretti, A., Gromov, M., Guffanti, D., Hagner, C., Hungerford, E., Ianni, Aldo, Ianni, Andrea, Jany, A., Jeschke, D., Kumaran, S., Kobychev, V., Korga, G., Lachenmaier, T., Lasserre, T., Laubenstein, M., Litvinovich, E., Lombardi, P., Lomskaya, I., Ludhova, L. (ORCID:0000000238750590), Lukyanchenko, G., Lukyanchenko, L., Machulin, I., Mantovani, F., Manuzio, G., Marcocci, S., Maricic, J., Martyn, J., Meroni, E., Meyer, M., Miramonti, L., Misiaszek, M., Montuschi, M., Muratova, V., Neumair, B., Nieslony, M., Oberauer, L., Onillon, A., Orekhov, V., Ortica, F., Pallavicini, M., Papp, L., Penek, Ö., Pietrofaccia, L., Pilipenko, N., Pocar, A., Raikov, G., Ranalli, M. T., Ranucci, G., Razeto, A., Re, A., Redchuk, M., Ricci, B., Romani, A., Rossi, N., Rottenanger, S., Schönert, S., Semenov, D., Skorokhvatov, M., Smirnov, O., Sotnikov, A., Strati, V., Suvorov, Y., Tartaglia, R., Testera, G.. 2020-01-21. Comprehensive geoneutrino analysis with Borexino. https://doi.org/10.1103/physrevd.101.012009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A proximity-focusing RICH detector for the ePIC Experiment at the EIC

The Electron-Proton/Ion Collider Experiment (ePIC) will be a large, multi-purpose detector to be installed at the Electron-Ion Collider (EIC) being built at Brookhaven National Laboratory. As robust particle identification (PID) capabilities are essential for fully realizing the EIC science program, ePIC contains several PID subsystems spanning different angular ranges. PID capability in the electron-going endcap is provided by a proximity-focusing Ring Imaging Cherenkov detector (pfRICH) designed to deliver at least 3σ separation between pions and kaons for momenta up to 7 GeV/ c . It will also aid with electron-hadron discrimination at low momentum and assist in the determination of the collision time (t 0 ). This contribution will summarize the design of the pfRICH as well as ongoing fabrication and component testing efforts. geant-based performance simulations will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗