Search NASA⌕ Search

DOE OSTI · 1604262

Assessment of the MACCS Code Applicability for Nearfield Consequence Analysis

Abstract

Three codes are used for comparisons in this report to evaluate the adequacy of MACCS in the nearfield, AERMOD, ARCON96 and QUIC. Test cases were developed to give a broad range of weather conditions, building dimensions and plume buoyancy. Based on the comparisons of MACCS with AERMOD, ARCON96 and QUIC across the test cases, the following observations are made: MACCS calculations configured with point-source, ground-level, nonbuoyant plumes provide nearfield results that bound the centerline, ground-level air concentrations from AERMOD, ARCON96, and QUIC. MACCS calculations with ground-level, nonbuoyant plumes that include the effects of the building wake (area source) provide nearfield results that bound the results from AERMOD and QUIC and the results from ARCON96 at distances >250 m. If using a point-source is too conservative and it is desired to bound the results from all three codes, another alternative is to use area source parameters in MACCS that are less than the standard values, i.e., an area source intermediate between the standard recommendation and a point source. All these options provide results from MACCS that are bounding for the test cases evaluated. Based on these observations, it appears that MACCS is adequate for use in nearfield calculations, given the correct parameterization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Clayton, Daniel James, Bixler, Nathan E.. 2020-02-01. Assessment of the MACCS Code Applicability for Nearfield Consequence Analysis. https://doi.org/10.2172/1604262

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗