Search NASA⌕ Search

DOE OSTI · 1614845

Verification and Validation of the STAT7 Code

Abstract

This document presents the verification and validation of the STAT7 Version 1.0 code which has been developed to perform the steady-state thermal hydraulic safety calculation of the MIT Research Reactor required upon conversion of the reactor from high enrichment uranium fuel to low enrichment uranium fuel. The key capabilites of the code including the statistical processing, water property generation, and thermal hydraulic solution are verified independently. While the first two capabilites are checked using statistical tests and NIST data tables, each component of the thermal hydraulic solution is verified using simple geometry test problems. The comparison between results obtained by the code and hand calculations on these problems shows that each of these components work correctly. Additionally, a comprehensive comparison between STAT7 Version 1.0 and PLTEMP/ANL Version 4.2 calculations for a five-channel test problem is performed for the validation. The good agreement between the obtained results for all thermal hydraulic parameters belonging to the fuel core region is achieved. An issue in bypass flowrate calculation was detected when both fin-friction and bypass flow claculations are involved. This problem can be corrected in a later version of the code, however, does not affect the application of STAT7 code as it has been used to date where the flow distribution in the core region and bypass channel is specified as an input parameter.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pham, Son. 2020-03-01. Verification and Validation of the STAT7 Code. https://doi.org/10.2172/1614845

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗