Search NASA⌕ Search

DOE OSTI · 1657688

Heat Loss Correction Factor for Fireball Yield Measurements

Abstract

Fireball yield calculations are performed using Taylor’s radius equation. However, at early times, the x-ray diffusion process has a significant effect on the size of the fireball, and at late times the shock wave degenerates into an acoustic wave. Thus, earlier research determined that the range of validity for Taylor’s equation was in the scaled time regime of 0.004–0.008 s. So, when performing a yield calculation, the only values that are analyzed are those that lie within that range of validity. While Taylor’s equations offer an approximation of the scaled yield, they also rely on several assumptions. For example, the equations assume that the shock wave is adiabatic, when, in fact, the first light pulse on the nuclear test films, which occurs as the shock wave is forming, suggests that the shock wave is not adiabatic. Furthermore, the amount of heat loss from the shock wave that occurs prior to the scaled time regime of 0.004–0.008 s can change significantly as a function of air density. This may cause the shock wave radius to be smaller relative to the assumed adiabatic shock wave. Therefore, the objective of this project was to determine the correction factor for heat transfer, which should be applied in order to produce a more accurate approximation of the weapon’s yield.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Costelle, Anna V.. 2020-08-14. Heat Loss Correction Factor for Fireball Yield Measurements. https://doi.org/10.2172/1657688

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Morgana Overview – NCERC Support for Dynamic Subcritical Experiments

The LANL Subcritical Experiments Program (SCE) recently executed the Morgana Subcritical Experiment at the NNSS. This was the first subcritical experiment executed by LANL for several years (since 2021). It was also notably the first that required SCE personnel to have FMH qualifications for a portion of the work conducted under nuclear criticality safety limits.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

AWSD Reactive Burn Model for the HMX‐Based High Explosive LX‐04

An Arrhenius–Wescott–Stewart–Davis (AWSD) reactive burn model is applied to describe shock initiation and detonation properties of the HMX-based high explosive LX-04. The parameters in the model are calibrated to data from multiple sources. The thermodynamic equations of state used in the model are calibrated to a combination of thermochemical calculations for HMX and LX-04 as well as experimentally-measured cylinder expansion results for LX-04. The kinetic parameters are calibrated to velocity data from gas gun experiments performed using EDC-32—a high explosive with the same chemical composition as LX-04 but different structural properties, and scaled rate stick data for PBX 9012. The AWSD model is shown to accurately describe the shock initiation and propagation of LX-04. Very good agreement is observed between the available experimental data and the AWSD model output. The presented results constitute an accurate LX-04 reactive burn model for use in engineering-scale models and simulations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Surface and Buried Thermal, and RGB Unexploded Ordnance Data Collection

This document provides a description of a data collection campaign of unexploded ordnance (UXOI) set. The dataset captures a controlled UAV imaging campaign designed to support detection of UXO across varied environmental conditions. Data were collected during three campaigns in Norris and Northeast Knoxville, Tennessee, using RGB, and thermal sensors mounted on Parrot UKR. In total, the dataset contains 9925 images, 26 full-motion video, and approximately 81.99 GB of data, collected across late spring/summer conditions, every hour during sunlight, and multiple surface contexts, including tall grass, short grass, gravel, as well as buried in sand, and other gravel mixtures. The collection was designed to capture thermal and visual variability relevant to UXO detection in agricultural land, bare earth, and subsurface. Review of the imagery showed that ordnance was most detectable during periods of changing solar input, especially approximately 10-60 minutes after sunrise, approximately 20-60 minutes after sunset, and 2-3 min after cloud cover interrupted prolonged solar heating. These conditions increased thermal contrast because many ordnance items retained or released heat differently than the surrounding vegetation and ground surface. This dataset provides a useful resource for developing and evaluating airborne UXO detection methods under realistic field conditions. All ordnance used in the study was inert, and thermal behavior may differ from that of live ordnance. In addition, variation in ordnance type, composition, and placement introduced differences in thermal response that should be considered when interpreting results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗