Search NASA⌕ Search

DOE OSTI · 1659160

Identifying Suspect Instrument Intervals Using Midnight Noise Time Histories

Abstract

With an intense work ethic, and high levels of devotion to their craft, seismologists continue to battle the elements and wrestle with complex logistics in their efforts to field instrumentation over the entire globe. We are fortunate to see data volumes accelerating in size, and quality continuing to improve; for example, universal timing issues can now be considered rare. However, instrument response issues are still common, and can hinder research that seeks to understand amplitudes of seismic wavefields. We are interested in using the accumulations of seismic data to develop models that will predict high frequency (0.2-20 Hz, and higher) signal amplitudes for explosion monitoring purposes over broad areas, which requires large data sets and extensive quality control. To identify response and station health issues, we have collected noise time histories for global seismic data, focusing on measurements near (but not restricted to) midnight to eliminate diurnal variations, and have manually determined time intervals that appear inconsistent with background behavior. We assign descriptive labels, but do not attempt to diagnose causes. We use these intervals to discard data. To date, we have examined 39,260 channels from 11,105 stations, heavily weighted toward IRIS holdings, dates through 2017 (depending on station, roughly the date we started our manual review), bands between 1 and 8 Hz, finding 24,733 anomalous time intervals. The great majority (90%) of these intervals appear to be shifts of constant offset, often bounded by times of known instrument changes, likely the result of poor documentation of response parameters at one of many stages between the field and the plotter. We hope these results can be of use to our colleagues, and would encourage community efforts to diagnose anomalous behavior, and fix poor responses. We also hope these results will support automation efforts, including application of supervised learning techniques.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Phillips, William Scott, Stead, Richard J.. 2020-09-08. Identifying Suspect Instrument Intervals Using Midnight Noise Time Histories. https://doi.org/10.2172/1659160

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗