DOE OSTI · 1660566
First Trials with EMPHASIS
Abstract
This report presents a series of three EMPHASIS trial problems we ran in March 2019, to demonstrate (1) that we can set up and run an SGEMP calculation, and (2) that we understand the nature and units of the input specifications and the output results. As these are the first EMPHASIS problems we have set up and run, we present some of the input decks and some of the lessons learned, to better orient a reader who might also be a new user of EMPHASIS. The EMPHASIS manual and the ITS manual are both good, but not complete enough to set up and run these applications. Substantial trial and error was still required. The trial problems are all based on an evacuated aluminum cylinder with 1 m inner radius and 1 m inner height. The cylinder is 100 mil thick. We take the axis of symmetry to be the z axis. The aluminum cylinder will be treated as perfectly conducting. The trial problems are (1) the cavity driven with a short pulse on an antenna at the center of the cavity, (2) the cavity driven by a prescribed short pulse of photocurrent injected normally from the bottom inside of the cylinder, and (3) the cavity driven by a prescribed short pulse of x-rays normally incident on the bottom outside of the cylinder.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Nelson, Eric Michael. 2020-08-30. First Trials with EMPHASIS. https://doi.org/10.2172/1660566
Cite the original work for its findings. Save a collection to share your selection of sources.