Search NASA⌕ Search

DOE OSTI · 1760650

Hydrogen Mitigation Process Installation at Nevada Solar One

Abstract

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Glatzmaier, Greg C. (ORCID:000000016432239X), Beckers, Koenraad F.. 2020-12-11. Hydrogen Mitigation Process Installation at Nevada Solar One. https://doi.org/10.1063/5.0031968

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Assessment of Cloud Mask Forecasts from the WRF-Solar Ensemble Prediction System: Preprint

Numerical weather prediction (NWP) models are important tools used by government agencies and the renewable energy enterprise to forecast solar radiation. Cloud prediction, a key process of NWP models, has the highest impact on the accuracy of solar forecasting. This study uses satellite observations from the National Solar Radiation Data Base (NSRDB) to evaluate the cloud mask forecast by the WRF-Solar Ensemble Prediction System (WRF-Solar EPS). Preliminary analysis of the data in 2018 demonstrates the need of further improvement in predicting thin and low-level clouds. The information obtained from this work will be used to enhance the WRF-Solar EPS in reproducing the cloud field over the contiguous U.S. and reducing solar forecasting errors.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evaluating Cell Temperature Models and the Effect of Wind Speed in PV System Capacity Testing: Preprint

Capacity testing is a routine procedure for assessing a photovoltaic system's performance relative to expectations. The most common test method involves fitting a regression model that predicts system output power using operating weather conditions including wind speed. Structural modifications to the regression model to incorporate wind in different ways improved the model's ability to fit measured system performance, but the observed improvements were small and unlikely to change the result of a capacity test. However, the results showed that the choice of reporting wind speed and inclusion or exclusion of wind speed in the performance model used as the test benchmark can significantly change the test result.

41 EE - Solar Energy Technologies Office (EE-4S)↗