A generalized forward fit for neutron detectors with energy-dependent response functions

Abstract

To date, most analysis of neutron time-of-flight data from inertial confinement fusion experiments has focused on the relatively small range of energies corresponding to the primary neutrons from DD and DT fusion, and have therefore employed instrument response functions (IRF’s) corresponding to monoenergetic 2.45-MeV or 14.03-MeV neutrons. For analysis of time-of-flight signals corresponding to broader ranges of neutron energies, accurate treatment of the data requires the use of an energy-dependent IRF. Here, this work describes interpolation of the IRF for neutrons of arbitrary energy, construction of an energy-dependent IRF, and application of this IRF in a forward fit via matrix multiplication. As an example of the application of this method, an analysis of synthetic data relevant to TT fusion experiments at the Omega Laser Facility is discussed. This example is used to illustrate the differences between a forward fit that uses an energy-dependent IRF and a forward fit that uses a monoenergetic IRF. Use of the energy-dependent IRF is shown to result in accurate inference of the fit parameters of interest.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mohamed, Z. L., Mannion, O. M., Hartouni, E. P., Knauer, J. P., Forrest, C. J.. 2020-12-01. A generalized forward fit for neutron detectors with energy-dependent response functions. https://doi.org/10.1063/5.0033117

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗