DOE OSTI · 1762428
Spent Crystalline Silicotitanate Storage Study—Post AP-105DF Processing
Abstract
A Tank-Side Cesium Removal (TSCR) system is under development by Washington River Protection Solutions to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. Tank waste supernate is filtered to remove suspended solids and then Cs is removed by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable after undetermined storage time. Previous testing with AP-105 simulant showed that rinsing the CST bed with 3 bed volumes (1.4 apparatus volumes [AVs]) of 0.1 M NaOH resulted in a dried bed that maintained flow characteristics indicative of ease of recovery. This study explored the intermediate conditions (between feed dried in place and the 1.4 AVs of 0.1 M NaOH rinse) to evaluate CST bed properties.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Fiskum, Sandra K., Westesen, Amy M., Peterson, Reid A.. 2021-01-01. Spent Crystalline Silicotitanate Storage Study—Post AP-105DF Processing. https://doi.org/10.2172/1762428
Cite the original work for its findings. Save a collection to share your selection of sources.