DOE OSTI · 1775346
The PRad windowless gas flow target
Abstract
In this work, we report on a windowless, high-density, gas flow target at Jefferson Lab that was used to measure $r_p$, the root-mean-square charge radius of the proton. To our knowledge, this is the first such system used in a fixed-target experiment at a (non-storage ring) electron accelerator. The target achieved its design goal of an areal density of 2$\times$10$^{18}$ atoms/cm$^2$, with the gas uniformly distributed over the 4 cm length of the cell and less than 1% residual gas outside the cell. This design eliminated scattering from the end caps of the target cell, a problem endemic to previous measurements of the proton charge radius in electron scattering experiments, and permitted a precise, model-independent extraction of $r_p$ by reaching unprecedentedly low values of $Q^2$, the square of the electron's transfer of four-momentum to the proton.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Pierce, J., Brock, J., Carlin, C., Keith, C., Maxwell, J., Meekins, D., Bai, X., Deur, A., Dutta, D., Gao, H., Gasparian, A., Gnanvo, K., Gu, C., Higinbotham, D., Khandaker, M., Liyanage, N., Meziane, M., Pasyuk, E., Peng, C., Punjabi, V., Xiong, W., Yan, X., Ye, L., Zhang, Y.. 2021-04-07. The PRad windowless gas flow target. https://doi.org/10.1016/j.nima.2021.165300
Cite the original work for its findings. Save a collection to share your selection of sources.