Abstract
Magnetically confined fusion plasmas with negative triangularity (δ) exhibit greater L-mode confinement than with positive δ. Recent experiments in the TCV and DIII-D tokamaks have correlated the confinement improvement to a reduction of fluctuations within the plasma core. We report on fluctuation measurements in the scrape-off layer (SOL) for -0.61 < δ < +0.64 in limited and diverted ohmic L-mode plasmas; these reveal a strong reduction in SOL fluctuation amplitudes at δ < -0.25, and, surprisingly, an almost full suppression of plasma interaction with the main-chamber first-wall, which could have important implications for the prospects of using negative δ plasmas as a reactor solution. An exploration of several physical mechanisms suggests that a reduced connection length—intrinsic to negative δ plasmas—plays a critical role in the origin of this phenomenon.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Han, Woonghee, Offeddu, Nico, Golfinopoulos, T., Theiler, Christian, Tsui, C.K., Boedo, J.A., Marmar, E.S.. 2021-02-19. Suppression of first-wall interaction in negative triangularity plasmas on TCV. https://doi.org/10.1088/1741-4326%2Fabdb95