Search NASA⌕ Search

DOE OSTI · 1779075

Nanoscale imaging of Gilbert damping using signal amplitude mapping

Abstract

Ferromagnetic resonance force microscopy (FMRFM) is a powerful scanned probe technique that uses sub-micrometer-scale, spatially localized standing spin wave modes (LMs) to perform local ferromagnetic resonance (FMR) measurements. In this work, we show the spatially resolved imaging of Gilbert damping in a ferromagnetic material (FM) using FMRFM. Typically damping is measured from the FMR linewidth. We demonstrate an approach to image the spatial variation of Gilbert damping utilizing the LM resonance peak height to measure the LM resonance cone angle. This approach enables determination of damping through field-swept FMRFM at a single excitation frequency. The extreme force sensitivity of similar to 2 fN at room temperature can resolve changes of Gilbert damping as small as ~2 x 10 -4 at 2GHz, corresponding to ~0.16Oe in FMR linewidth resolution. This high sensitivity, high spatial resolution, and single frequency imaging of Gilbert damping creates the opportunity to study spin interactions at the interface between an insulating FM and a small volume of nonmagnetic material such as atomically thin two-dimensional materials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wu, Guanzhong, Cheng, Yang, Guo, Side, Yang, Fengyuan, Pelekhov, Denis V., Hammel, P. Chris. 2021-01-25. Nanoscale imaging of Gilbert damping using signal amplitude mapping. https://doi.org/10.1063/5.0023455

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

STM/S Grid LDOS Data and Analysis Code for Deciphering Majorana Zero Modes in Topological Superconductor

This dataset provides raw millikelvin scanning tunneling microscopy/spectroscopy (STM/S) grid spectroscopy data and Python analysis scripts supporting the manuscript “Deciphering Majorana Zero Modes in Topological Superconductor FeTe0.55Se0.45 with Machine-Learning-Assisted Spectral Deconvolution.” The dataset includes a raw grid spectroscopy file acquired on FeTe0.55Se0.45 at 40 mK under magnetic field, together with Python/Jupytext analysis scripts used for STM/S data processing, visualization, spectral deconvolution, Lorentzian peak fitting, feature extraction, machine-learning-assisted clustering, and figure generation. These files support the analysis of vortex-core local density of states and the identification of zero-bias-peak-related spectral components from complex in-gap states. The dataset is intended to provide a citable archival record of the data and analysis code associated with the published manuscript and to support transparency and reproducibility of the reported STM/S and machine-learning workflow.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dielectric Resonator Design for Low Power and Low Temperature Microwave Plasma

Waveguide-based microwave plasmas generally operate at high temperatures (2000 - 6000K)[1], making it difficult to directly interface solid materials with the plasma without significant thermal damage. Dielectric microwave resonators (DMRs), long studied for wave-based manipulation of electromagnetic radiation for telecom and optics, can focus radiation to extremely small mode volumes, creating intense localized fields with low-power input.[2] This phenomenon can be used for applications ranging from efficient plasma electronics to near-ambient plasma-materials interactions. Such DMR-based plasmas have been demonstrated a handful of times in the literature, but the majority of research towards this utilize the lowest frequency resonance mode.[3], [4], [5] By carefully controlling the geometry of cylindrical resonators, a variety of electromagnetic modes can be excited. In this work, COMSOL Multiphysics simulations are used to study the electric field enhancement and absorption properties of CaTiO3 DMRs as a function of geometry and excitation frequency. Whereas previous studies have utilized the HEM111 resonance frequency to drive low power plasma excitation, we find that higher order resonance frequencies are more effective at field enhancement and result in less power loss within the dielectric material, hence less wasted heating. The effectiveness of these modes is also geometry dependent and can be computationally optimized for plasma generation. Complementing these computational efforts, we demonstrate a new closed-system reactor design built in a WR-650 waveguide and experimentally demonstrate the formation of atmospheric argon microwave plasma using < 30 W input power on DMR dimers. We observe a shifting resonance frequency as the DMRs heat in response to microwave excitation and develop a Python-based lock-in mechanism to effectively track the DMR resonance over time, leading to stable plasma operation. We use infrared thermal imaging to monitor the temperature of the DMR dimers and surrounding quartz chamber, demonstrating thermal temperatures < 60 degreesC. Finally, we utilize optical emission spectroscopy (OES) to probe the plasma properties as a function of the resonance mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗