Search NASA⌕ Search

DOE OSTI · 1782574

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

Abstract

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shah, Niral P., Marleau, Peter, Fessler, Jeffrey A., Chichester, David L., Wehe, David K.. 2021-02-18. Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements. https://doi.org/10.1109/tns.2021.3060071

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

FPMS_XPeRT_INL_Poster

As nuclear energy expands and experimental programs increasingly rely on the facilities at Idaho National Laboratory (INL) for reactor and fuel testing, research capabilities must also expand to meet these demands. A new Fission Product Monitoring System (FPMS) has been deployed at the Advanced Test Reactor (ATR) at the Auxiliary Lead-out Experiment (ALE) House to support this expanding fuel testing mission. By tracking gaseous fission products releases from test fuel in near real-time, release rates, calculated from FPMS data, can be used to characterize the effectiveness of fuel cladding, especially for Tri-structural Isotropic (TRISO) fuel concepts. The new iteration of the FPMS supports up to 14 fission product monitors for online fission-product tracking via gamma-ray spectroscopy of the experiment’s effluent gas. Each monitor consists of a nominally 10% HPGe detector housed in a copper-lined lead shield with a warm gas trap. The new system features gamma-ray count rate information with a five-second temporal resolution and provides isotopic activity every five minutes, capable of resolving multiple overlapping fission product releases over a broad range of activities in near real-time. This work includes data from ATR cycle 175D data to demonstrate these capabilities. The hourly resolution data shows general trends and significant releases over the cycle, while the 5-minute resolution data allows for a more detailed examination of events due to unexpected particle releases.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Overview of IMPACT Data Acquisition System and Data Reduction Process

This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Thermal Performance of Neutron Sensor Qualification Device

The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗