DOE OSTI · 1782682
Diffusion Bonded Hydrogen Pre-Cooler Pressure Testing
Abstract
Diffusion bonded heat exchangers, also known as printed circuit heat exchangers (PCHEs), have numerous benefits over traditional shell and tube heat exchangers including high pressure containment, a compact size with 1000 to 5000 m 2 of surface area per unit volume, and lower costs. One emerging application is in hydrogen vehicle fueling stations as a hydrogen pre-cooler (H2PC™) where the hydrogen is cooled at pressures up to 900 bar. These pre-coolers must be able to withstand pressure cycling over 10 5 cycles during the fueling station lifetime without degradation of their pressure vessel integrity that could result in hydrogen leakage.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Lance, Blake W., Carlson, Matthew D., Amogne, Dereje. 2021-04-01. Diffusion Bonded Hydrogen Pre-Cooler Pressure Testing. https://doi.org/10.2172/1782682