Search NASA⌕ Search

DOE OSTI · 1804753

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

Abstract

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hennig, Wolfgang, Hoover, Shawn. 2021-06-02. White Rabbit Time Synchronization for Radiation Detector Readout Electronics. https://doi.org/10.1109/tns.2021.3085242

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Design-informed neutronics assessment of long-lived fission product transmutation in a tokamak fusion reactor blanket

This study presents a neutronics-based assessment of the feasibility and viability of transmuting six major long-lived fission products (LLFPs) from light-water reactors, namely 99 Tc, 129 I, 79 Se, 93 Zr, 126 Sn, and 135 Cs, within the blanket region of a tokamak fusion reactor, using the MIT ARC design as a concrete fusion configuration. Monte Carlo neutronics simulations were performed to evaluate LLFP transmutation and to compare the results with a reference boiling water reactor (BWR). The results indicate that transmutation of all six LLFPs is neutronics-feasible in fusion reactors, with transmutation half-lives significantly shorter than their natural decay half-lives. For elemental targets, transmutation of 135 Cs, 126 Sn, and 93 Zr was found potentially viable, as the net mass transmuted exceeded that achievable in the reference BWR under identical target volume and irradiation time. When isotopically separated targets were considered, transmutation of 126 Sn and 93 Zr appeared potentially viable. A parametric study demonstrated that plasma geometry modifications can enhance local neutron flux, increasing the transmuted 93 Zr mass by approximately 33% and reducing the transmutation half-life from approximately 240 years to 180 years. Repositioning the target and adjusting material layer thickness reduced the transmutation half-life of 93 Zr to 67 years and increased the net mass transmuted by a factor of 50. Furthermore, these results demonstrate that fusion reactors can enable LLFP transmutation beyond the practical limits of thermal fission reactors and highlight the critical role of reactor and blanket design optimization. Engineering and fuel-cycle considerations required for deployment are beyond the scope of this neutronics-focused study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A hybrid Monte Carlo-deterministic second moment method with efficient variance reduction

In this work, we present a hybrid method that combines Monte Carlo with deterministic finite element methods to solve a linear Boltzmann transport equation. Our hybrid method runs orders of magnitude faster than Monte Carlo, without sacrificing accuracy, for a proxy problem from radiative transfer that contains both optically-thick and optically-thin material. We believe that this is the first demonstration of a hybrid Second Moment Method in more than one spatial dimension, the first to consider more than one material, and the first to use variance reduction. Our variance reduction approach arises from an asymptotic analysis in which we show that the magnitude of the scattering source grows without bound. We transform the problem to compute the deviation of the radiation intensity from isotropy. The magnitude of the source in the transformed problem is bounded, and the quality of the hybrid method solution is dramatically improved by a substantial reduction in the variance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗