Abstract
Plasma accelerators can generate ultra-high-brightness electron beams that open the door to light sources with a smaller physical footprint and properties un-achievable with conventional accelerator technology. In this paper, we show that electron beams from Plasma WakeField Accelerators can generate few-cycle coherent tunable soft x-ray pulses with TW peak power and a duration of tens of attoseconds, an order of magnitude more powerful, shorter, and with better stability than state-of-the-art X-ray Free Electron Lasers (XFELs). Such a light source would significantly enhance the ability to experimentally investigate electron dynamics on ultrafast timescales, having a broad-ranging impact across multiple scientific fields. Rather than starting from noise as in typical XFELs, the x-ray emission in this approach is driven by coherent radiation from a pre-bunched, high peak current electron beam of attosecond duration. This relaxes the restrictive tolerances that have hindered progress toward utilizing plasma accelerators as coherent x-ray drivers thus far, presenting a new paradigm for advanced accelerator light source applications.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Emma, C., Xu, X., Fisher, A., Robles, R., MacArthur, J. P., Cryan, J., Hogan, M. J., Musumeci, P., White, G., Marinelli, A.. 2021-07-29. Terawatt attosecond x-ray source driven by a plasma accelerator. https://doi.org/10.1063/5.0050693
Cite the original work for its findings. Save a collection to share your selection of sources.