DOE OSTI · 1810484
Residual Insoluble Solids Expected from Saltcake Dissolution
Abstract
A review of previous SRS saltcake dissolution and characterization studies was performed to inform the analysis of the amount of residual insoluble solids that may result from saltcake dissolution. A realistic value covering most cases for the maximum volume of a settled layer of residual insoluble solids that would result from dissolution of a volume of saltcake was calculated as 0.08 mL/mL (8 vol%). Applying factors to account for dissolution test uncertainty and differences between in-tank settling and laboratory testing, the recommended value for a settled layer of residual insoluble solids that would result from dissolution of a volume of saltcake is 0.16 mL/mL (16 vol%). This should apply to dissolution of saltcake with typical minimal amounts of entrained sludge but may not apply to saltcake with significant sludge. As it is composed of primarily non-radioactive isotopes, the precipitated aluminum hydroxide material does not contribute to the heat load.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Martino, Christopher J.. 2021-07-01. Residual Insoluble Solids Expected from Saltcake Dissolution. https://doi.org/10.2172/1810484
Cite the original work for its findings. Save a collection to share your selection of sources.