Multiplexing of frequency-modulation spectroscopy by spread-spectrum codes, demonstrated in continuous-wave LIDAR
Abstract
Frequency-modulation spectroscopy (FMS) is generally suited to code-division multiplexing, and we demonstrate that capacity in a form of continuous-wave LIDAR, utilizing a sharp CO 2 absorption transition at 1.6 µm in simple ranging setups. The approach retains the advantages of FMS, including coherent detection and good rejection of broad absorption backgrounds. Extensions of this multiplexed approach to the continuous, simultaneous detection of several transitions would come by transmitting an encoded combination of frequency-modulated carriers, each tuned to detect a unique absorption transition. Signal analysis at the receiver involves a simple process of de-multiplexing that, in a general application, reveals targets at various distances and the absorption-related FMS signals in between.