Volumetrically Absorbing Thermal Insulator (VATI) for High-temperature Receivers

Abstract

This project seeks to exploit volumetric absorption of concentrated solar irradiation in a thin, high-temperature, thermally conductive medium. High efficiency thermal conversion is achieved by volumetric absorption of both incoming solar irradiation (short wavelength) and emitted irradiation (long wavelength), demonstrating a volumetrically absorbing thermally insulating (VATI) effect. The thermalized energy is conducted to the back wall, enclosing the working fluid (molten salt or supercritical CO 2 ). Reliance on conductive thermal transport requires a thermally conductive medium, in the absence of which large temperature gradients drive losses due to emission. The project’s outcomes are important to realize a cost-effective approach to reduce optical and thermal losses from CSP receivers at high temperatures (720°C). High-temperature stable and commercially available porous SiC structures (open-cell foams) were explored as a volumetrically absorbing and thermally insulating layer. To the best of our knowledge, the current state-of-the-art for industrially deployed coatings is Pyromark. However, Pyromark suffers degradation at 700+°C and diurnal temperature changes. This necessitates periodic recoating, and the downtime increases the overall levelized cost of energy (LCOE) production. On the other hand, contemporary research activities have generated significant advances in the development of selective emitter coatings, which present challenges with costs, scalability, and stability. The pursued approach alleviates these concerns by developing a receiver that utilizes the inherent structure of high-temperature stable porous materials to enable robust and cost-effective receivers which require no periodic maintenance downtimes. The overall goal of the project is to experimentally demonstrate a figure of merit (FOM) of 0.92 at a temperature of 720°C and solar irradiation of 1000x concentration with porous receivers. The relevant crystallographic (phase) optical and thermal properties of porous SiC were first characterized. Second, the 3-D geometry of the porous SiC was analyzed using micro-X-ray tomography and converted to CAD data using image processing analysis. Utilizing this 3-D geometry and relevant optical/thermal properties, Monte Carlo- Ray Tracing (MCRT) analysis was performed to extract important parameters governing solar-thermal energy conversion such as extinction coefficient (β, 1/m), scattering albedo (ω) and the scattering phase function (Φ). These properties were then integrated into an in-house radiative and conduction transport model to solve for temperature and transport fluxes characterizing the solar-thermal energy conversion. This model was utilized to predict the FOM for various SiC porous geometries and to identify the highest possible FOM. Testing of the optimized porous structures will be accomplished with a custom-built high-accuracy (< ±4%) FOM measurement test-stand and a 1000x solar concentrator. When neglecting convective losses and resistance at the open boundary and the back wall, the optimized SiC foam leads to a FOM of 0.84. This FOM does not surpass the performance of Pyromark 2500. Yet, conversely to Pyromark 2500, SiC is stable at high temperatures and does not degrade over time. Also, it is possible to boost the FOM of SiC by engineering its effective thermal conductivity and its scattering albedo. A FOM of 0.92 is predicted for an optimized foam by accounting for convective losses and resistance at the open boundary and the back wall. This largely exceeds the FOM of Pyromark 2500 (~0.86) predicted by neglecting convective losses and resistance. Therefore, further engineering of the foam could lead to unprecedented FOMs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rao, Sameer R., Francoeur, Mathieu, Park, Keunhan. 2021-03-17. Volumetrically Absorbing Thermal Insulator (VATI) for High-temperature Receivers. https://doi.org/10.2172/1814849

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Technoeconomic Analysis Round Robin of a Retrofit of the Ivanpah Concentrating Solar Plant with a Molten-Salt System with Thermal Energy Storage

While the fidelity of technoeconomic analysis (TEA) models for concentrating solar thermal systems has improved in recent years, there is a lack of consensus on the specific inputs used to forecast performance of a newly built tower system due to a lack of validations and post-mortems available to the public. This effort is a joint initiative between multiple international organizations to validate and compare their TEA models. The specific case study is a proposed retrofit of one unit of the Ivanpah Solar Energy Generating System to include molten-salt storage, replacing the steam generation system with a molten-salt receiver, salt-to-steam heat exchanger train, and new balance of plant while keeping the existing steam turbine, solar field, and interconnection in place, using plant data for calibration. This manuscript discusses several of the agreed-upon assumptions for this study as well as a preliminary analysis from prior work that motivates the study.