Search NASA⌕ Search

DOE OSTI · 1823424

Storage Futures Study - Distributed Solar and Storage Outlook: Methodology and Scenarios

Abstract

This presentation discusses the fourth report in NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This report describes the expanded capabilities of the Distributed Generation Market Demand (dGen) model to analyze the economics of distributed (behind-the-meter) PV paired with battery storage systems and presents projections of adoption for the contiguous United States out to 2050 under a range of scenarios. These scenarios use technology cost and performance assumptions consistent with the National Renewable Energy Laboratory’s 2020 Standard Scenarios paired with updated battery cost projections and existing policies. Additional scenarios evaluate sensitivities to the value of backup power and DER compensation mechanisms, collectively characterizing the future potential for behind-the-meter storage and identifying key drivers of adoption. Adoption projections of DER and battery storage at high spatial and temporal resolution, as presented in this report, can enable informed planning of technical infrastructure that can help planners capture the benefits and mitigate challenges to support the ongoing trend toward distributed electricity generation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Prasanna, Ashreeta, McCabe, Kevin (ORCID:0000000191272674), Sigrin, Ben, Blair, Nate. 2021-09-27. Storage Futures Study - Distributed Solar and Storage Outlook: Methodology and Scenarios. https://www.osti.gov/biblio/1823424

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Impact of Emergency Diesel Generator Reliability on Microgrids and Building-Tied Systems

Microgrids are an emerging alternative as an energy backup system for critical electric loads and have improved performance compared to the traditional architecture where a single emergency diesel generator is tied to an individual building. Both architectures are dependent on the reliability of their individual generators and a quantitative and realistic comparison of the overall system reliability of the two architectures is lacking. Using recently published work on emergency diesel generator finite reliability, a quantitative methodology is presented to compare the reliability of a microgrid architecture based on centralized emergency diesel generators to the traditional approach of generators tied to individual buildings. Three system reliability performance metrics are calculated as a function of outage duration: (1) probability to meet 100% of the critical load; (2) expected fraction of lost load; and (3) probability to meet the highest priority critical loads. It is shown that stand-alone building-tied emergency diesel generators systems, even when two emergency diesel generators are used per building, cannot provide the reliability required to sustain critical loads for a grid outage lasting multiple days. Due to their network configuration and ability to share load, diesel generator-based microgrid configurations are estimated to have = 93% probability of powering all buildings for a 2-week outage there the individual building-tied emergency diesel generator architecture has a =20% probability. Microgrids do present other susceptibilities that are site specific and should be considered including vulnerabilities associated with the on-campus distribution system and cybersecurity.

backup power↗

Emergency Diesel Generator Backup Power Systems for Military Bases

Backup power systems on military installations must provide reliable power during a grid outage. The risks of blackouts and loss of electric power are not new. Outages of just a few hours are well known, but longer duration outages are becoming more frequent. The U.S. Army, Navy, and Air Force now require backup power from one to two weeks. For multiday outages, the reliability of emergency diesel generators will have a significant impact on the installation’s backup power system’s ability to provide power for critical missions.

backup power↗