Abstract

For this Icy Moon project, we designed, procured, built, tested and used a compact ICI instrument. This instrument has several technical advances, including a compact form factor that uses fiber arrays to relay light to six APDs. This enables a single data acquisition to measure eleven unique baselines simultaneously. The DAQ is well-synchronized and provides a path forward to even more channels. The combination of a bright LED, a sinusoidal target and cylindrical optics enables high-SNR measurements based on a known formula: a 25-ms measurement should have an SNR of 188 on the baseline zero signal. This rapid measurement time should enable two-dimensional operation and obviate the impact of temperature drifts. However, the experiment did not detect a coherence signal on any baseline (see Section Single-shot measurement results).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Poyneer, Lisa A., Bauman, Brian, Armendariz, Jaime Ruz. 2021-10-27. Icy Moon Project (Final Report). https://doi.org/10.2172/1833207

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗