Accessing Wi-Fi Data for Occupancy Sensing

Abstract

A key issue for saving energy in buildings is to assure that delivery of energy services matches building occupancy as closely as possible, to assure that energy is not wasted providing the services to empty rooms or buildings, and to assure that needed services are provided during all times when desired. Accomplishing this to date has been significantly hampered by a lack of inexpensive mechanisms to obtain and use building-wide and more granular data about occupancy. In recent years, the concept of inferential (or implicit) sensing has been proposed and explored to use data from IT systems that already exists in most buildings, to obtain data that are not perfect, but are nearly free to obtain. Past work by LBNL and others has primarily demonstrated the principle and potential for this, with a primary focus on data from Wi-Fi networks as the best near-term opportunity for inferential sensing from IT networks. This is due to its near-ubiquity, ease of explanation to many audiences, relative uniformness in deployment, low latency of detection, clear ways to mitigate privacy and security, and other benefits (Price et al., 2015). While the potential and value are clear, researchers or building managers who want to obtain the data lack a source of information to understand what data might exist, what devices may have it, and what mechanisms are available to obtain the data. The purpose of this report is to fill that gap. The report begins with a review of institutional issues in collecting such data, including very real concerns about privacy and IT security. It then describes the various system architectures used in Wi-Fi systems in commercial buildings today, and a variety of mechanisms that can be used to obtain information from them, including examples of how to use them, and sample output. Next is a summary of how to use such data for several different purposes, from retrospective analysis to dynamic building operation, and a conclusion. An appendix provides additional detail on specific mechanisms available from major equipment manufacturers. The mechanisms specified in this report can be used by building owners and operators to confirm proper operation and uncover any issues or unexpected conditions as a resource for building owners and researchers interesting in utilizing inferential sensing data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pritoni, Marco, Nordman, Bruce, Piette, Mary Ann. 2017-03-01. Accessing Wi-Fi Data for Occupancy Sensing. https://doi.org/10.2172/1833835

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Building the Business Case with JUSTIFI: Quantifying Multiple Benefits in the Automotive Industry

The Michigan State University Industrial Training and Assessment Center (MSU ITAC) conducted a pilot study at an automotive parts manufacturer in Michigan. The study identified energy-productivity enhancements through the application of the JUSTIFI software. Key recommendations included replacing six inefficient rooftop units (RTUs) with a new air rotational unit. By quantifying operational savings for this project, the expected payback period went from 6.6 years to 1.4 years. Additionally, the installation of variable frequency drives (VFDs) on condenser tower motors was suggested. By including all operational benefits, the payback period was reduced from 8.2 years to 1.3 years. This comprehensive analysis aims to bolster the manufacturer's goals of reducing energy while enhancing overall operational efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Physics-Informed Reinforcement Learning Framework for Economic-Thermal Co-Optimization of Crypto Mining Data Centers: Preprint

The rapid expansion of cryptocurrency mining has created a new class of high-density data centers characterized by extreme thermal flux and high sensitivity to volatile economic markets. Traditional thermal management strategies, typically reliant on rule-based control, maintain static setpoints that fail to account for fluctuating electricity prices and cryptocurrency values - factors critical to mining profitability. To address this, we present a physics-informed reinforcement learning (PIRL) framework for economic-thermal co-optimization in crypto mining data centers. This framework consists of a proximal policy optimization (PPO) agent, a virtual testbed powered by high-fidelity physics-based models, and an interactive frontend dashboard. The PPO agent is trained using the virtual testbed and strict hardware safety limits. This physics-informed approach allows the agent to learn a stochastic policy that dynamically balances mining revenue against operational costs by co-optimizing HVAC cooling setpoints and IT computational hashrate. The simulation results demonstrate that the integrated framework achieved an 8.62% increase in net operational profit compared to traditional baseline strategies while strictly adhering to safety-critical temperature constraints (coolant supply temperature < 32 degrees C). This work provides a scalable template for the deployment of reinforcement learning in mission critical facilities where economic volatility and physical safety must be managed simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗