DOE OSTI · 1842389
Micrometer-accuracy 2D displacement interferometer with plasmonic metasurface resonators
Abstract
In this Letter, a high-accuracy, two-dimensional displacement sensor is proposed, designed, and demonstrated based on the concept of an extrinsic Fabry–Perot Interferometer. The sensor is composed of two bundled single-mode optic fibers in parallel and two plasmonic metasurface resonators inscribed on a gold substrate via a focused ion beam. The fiber end surface and the metasurface are in parallel with a small cavity between. The cavity change or Z -component displacement is determined from the pattern of interference fringes. The X -component displacement, perpendicular to the Z component, is identified from wavelength-selective metasurface resonators, which possess unique resonant wavelengths due to different nanostructure designs. The sensor was calibrated with six displacements applied through a three-axis precision linear stage. Test results indicated that the proposed interferometer can measure displacements with a maximum error of 5.4 µm or 2.2%.
Keep this discovery
Explore connections, maps & timelines
Guo, Chuanrui (ORCID:0000000271412972), Zhang, Yuchao, Klegseth, Matthew, Gao, Jie, Chen, Genda (ORCID:0000000206584356). 2020-11-24. Micrometer-accuracy 2D displacement interferometer with plasmonic metasurface resonators. https://doi.org/10.1364/ol.412130
Cite the original work for its findings. Save a collection to share your selection of sources.