Titanium Material Comparison for Second Target Station Moderators
Abstract
Two titanium alloys, Ti 15-3-3-3 and Grade 5 Ti, have been analyzed for their neutronic differences after being exposed to neutron fluxes from a 5-year operational period in the Second Target Station (STS)moderators. There are several differences in the original composition of the two alloys where Ti 15-3-3-3contains Cr and Sn and Grade 5 Ti does not. The differences in original composition propagate through the analysis to yield discrepancies in decay power density and decay gamma intensity density of more than a factor of 3.5 at some times during operation. Immediately after the 5-year operational period, Ti 15-3-3-3has a factor of 3.59 higher intensity of high-energy decay gammas than Grade 5 Ti, and Ti 15-3-3-3 also has a factor of 3.53 higher decay power than Grade 5 Ti. After 1 year of shutdown, Ti 15-3-3-3 has a 48% higher intensity of high-energy decay gammas and a 86% greater decay power density when compared with Grade 5 Ti. The quantities-of-interest in this report are per unit volume and the overall volume of titanium should be considered when making engineering judgment on final titanium alloy selection.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
McClanahan, Tucker. 2022-02-01. Titanium Material Comparison for Second Target Station Moderators. https://doi.org/10.2172/1881127
Cite the original work for its findings. Save a collection to share your selection of sources.