Abstract
This report describes the improvements to the Feasible Actuator Range Modifier (FARM) component of the RAVEN-based HYBRID framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON plug-in that solves the power dispatch problem. The solution involves economically optimal dispatches that satisfy the limits on production variables and corresponding rates of variation (explicit constraints) as well as the limits on the process variables tied to the service life of equipment (implicit constraints). The problem can be addressed as a two-stage process, i.e., HERON power dispatcher estimates a solution that meets explicit constraints (low-resolution physics), whereas FARM uses the simulation outcomes of HYBRID high-fidelity model to capture the system dynamic response and enforce implicit constraints (high-resolution physics). The initial version of the code (FARM-Alpha) was released by Argonne National Laboratory in January 2021 followed by FARM-Beta (January 2022) and FARM-Gamma (April 2022).
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Wang, Haoyu, Ponciroli, Roberto, Dave, Akshay J., Vilim, Richard B.. 2022-07-31. Control system for multi-system coordination via a single reference governor. https://doi.org/10.2172/1881455