DOE OSTI · 1888534
Linear and nonlinear benchmarks between the CLT code and the M3D-C1 code for the 2/1 resistive tearing mode and the 1/1 resistive kink mode
Abstract
Here, the linear and nonlinear benchmarks between the CLT code and the M3D-C1 code for the 2/1 resistive tearing mode and the 1/1 resistive kink mode are presented. CLT is an explicit finite difference code, while M3D-C1 is an implicit finite element code. Although the implementations of CLT and M3D-C1 are totally different, we find that the simulation results of the resistive-kink mode and the m/n=2/1 tearing mode from M3D-C1 and CLT are almost the same, including the linear and nonlinear growth rates, the mode structures, the nonlinear saturation levels, the Poincare plots, and the scaling laws. This confirms that the nonlinear results for the 1/1 resistive-kink mode and 2/1 tearing mode are accurate and reliable.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Zhang, W., Jardin, S. C., Ma, Z. W., Kleiner, A., Zhang, H. W.. 2021-08-11. Linear and nonlinear benchmarks between the CLT code and the M3D-C1 code for the 2/1 resistive tearing mode and the 1/1 resistive kink mode. https://doi.org/10.1016/j.cpc.2021.108134
Cite the original work for its findings. Save a collection to share your selection of sources.