DOE OSTI · 1897666
Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools: Case Studies of U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001
Abstract
Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP® reference collection website at https://mcnp.lanl.gov. Whisper-1.0 was originally developed in 2014 and used to assist with nuclear criticality safety validation at Los Alamos National Laboratory. Whisper was upgraded in 2016 to Whisper-1.1 and prepared for release with MCNP6.2 [References 3-5]. Whisper contains a library of over 1100 critical experiment benchmarks and quantifies neutronic similarity of an application to benchmarks in the library. Using highest similarity benchmarks, Whisper computes a calculational margin (CM) encompassing of the worst-case bias and bias uncertainty at a 99% confidence level for each application. In addition, portions of the margin of subcriticality (MOS) for nuclear data uncertainty and potential code errors are computed. The baseline upper subcritical limit (USL) computed by Whisper is comprised of the CM, MOS nuclear data , and MOS code errors . The Whisper baseline USL is absent a portion of the MOS due to the area of application, which is applied based upon judgment by the criticality safety analyst. An objective of this paper is to present the baseline USL, CM and portions of the MOS as computed by Whisper for comparison with similar sensitivity/uncertainty tools, such as those used by IRSN and ORNL. An initial comparison involved four critical experiment benchmarks: HEU-MET-FAST-013-001, HEU-SOLTHERM-001-008, PU-MET-FAST-022-001, AND PU-SOL-THERM-001-001, which have been documented in References 10-13. This study extends the comparison to include cases U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM- 004-001.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Alwin, Jennifer. 2021-07-01. Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools: Case Studies of U233-SOL-THERM-001-001, MIX-COMP-THERM-001-001, IEU-MET-FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001. https://doi.org/10.2172/1897666
Cite the original work for its findings. Save a collection to share your selection of sources.