DOE OSTI · 1926747
Mapping the 3D position of battery cathode particles in Bragg coherent diffractive imaging
Abstract
In Bragg coherent diffractive imaging, the precise location of the measured crystals in the interior of the sample is usually missing. Obtaining this information would help the study of the spatially dependent behavior of particles in the bulk of inhomogeneous samples, such as extra-thick battery cathodes. This work presents an approach to determine the 3D position of particles by precisely aligning them at the instrument axis of rotation. In the test experiment reported here, with a 60 µm-thick LiNi 0.5 Mn 1.5 O 4 battery cathode, the particles were located with a precision of 20 µm in the out-of-plane direction, and the in-plane coordinates were determined with a precision of 1 µm.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Shabalin, A. G., Zhang, M., Yao, W., Rysov, R. (ORCID:0000000275890808), Ren, Z., Lapkin, D. (ORCID:0000000306808740), Kim, Y. -Y. (ORCID:0000000161029518), Assalauova, D., Mukharamova, N., Sprung, M., Vartanyants, I. A. (ORCID:0000000203408234), Meng, Y. S., Shpyrko, O. G.. 2023-02-16. Mapping the 3D position of battery cathode particles in Bragg coherent diffractive imaging. https://doi.org/10.1107/s1600577523000814
Cite the original work for its findings. Save a collection to share your selection of sources.